Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001594730

Tests6
Approved0
Failures6

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-08-11 19:43 23949 638905309390809318-9065 SB-VBB-050_P04 Fail View
2025-08-11 19:44 23950 638905309946810669-6482 SB-VBB-050_P04 Fail View
2025-08-11 19:51 23951 638905314699455379-6386 SB-VBB-050_P04 Fail View
2025-08-11 20:22 23952 638905333615580085-4451 SB-VBB-050_P04 Fail View
2025-08-11 20:24 23953 638905334233131666-2319 SB-VBB-050_P04 Fail View
2025-09-17 14:03 26699 638937073865406383-7990 SB-VBB-050_P04 Fail View

Test 26699

Result
Fail
Date
2025-09-17 14:03
Article
SB-VBB-050_P04
ID record
638937073865406383-7990
ID production
48297
Temperature
26.64
Humidity
37.21
Test duration
3
Error ID
077
Error text
DMM: Měření napětí: +3V3_PERM (TP41/TP65)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 48297 Pass
0.2 Uložení ID obsluhy 0736 Pass
0.3 Uložení teploty okolí 26.64 Pass
0.4 Uložení vlhkosti okolí 37.21 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) SB-VBB-050_P04 Pass
0.6 DMM: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.7 NZ3: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.8 EL: Status? 0000000000000000 xxxxxxxxx000000x Pass
1.1 NZ3: Měření napětí: Zkrat? 2.23355 < 4.9 Pass
1.2 DMM: Měření napětí: +3V3_PERM (TP41/TP65) 2.87861241 3.25 3.35 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (6)
DateValueMinMax
2025-08-11 19:43 48297
2025-08-11 19:44 48297
2025-08-11 19:51 48297
2025-08-11 20:22 48297
2025-08-11 20:24 48297
2025-09-17 14:03 48297