Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001676337

Tests7
Approved0
Failures7

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-09-05 10:12 25807 638926566915049846-9147 S0001055 Fail View
2025-11-06 17:12 40608 638980422898917957-2183 S0001055 Fail View
2026-07-09 16:26 77807 639192111310406157-9403 S0001055 Fail View
2026-07-09 16:27 77808 639192111929755589-4514 S0001055 Fail View
2026-07-09 16:28 77809 639192112575286326-7623 S0001055 Fail View
2026-07-09 16:29 77810 639192113242717822-3402 S0001055 Fail View
2026-07-09 16:30 77811 639192113957316372-2106 S0001055 Fail View

Test 25807

Result
Fail
Date
2025-09-05 10:12
Article
S0001055
ID record
638926566915049846-9147
ID production
49348
Temperature
28.04
Humidity
45.26
Test duration
54
Error ID
359
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 49348 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 28.04 Pass
0.4 Uložení vlhkosti okolí 45.26 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.736565229 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1005.82257 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001356874 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02464286 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9479575 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9962195 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8373271 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.00332032 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30829745 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30828467 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.68561327 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.68147538 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.68198618 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.557141778 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7550966 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02547092 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.128995 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5756627 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3191447 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.61835841 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02542083 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3837 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4084 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2040 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2037 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2009 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2031 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2028 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30348657 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00350074676 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30470109 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00349001758 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30332115 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00363176418 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30348258 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00352200907 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 75 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.2021 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.2021 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0095797 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1984 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1984 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0090078 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1927 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1984 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0088266 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.000619238999 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2270 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2264 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2266 Pass
20.0.5 Analysis: VA VA[2270] 2210 2340 Pass
20.0.6 Analysis: VB VB[2264] 2210 2340 Pass
20.0.7 Analysis: VC VC[2266] 2210 2340 Pass
20.1.3 TestSW: [ADC_PA1] sense B 2100 1999[VB] 2099[VB] Fail
20.1.2 TestSW: [ADC_PA0] sense A 2439 2435[VA] 2535[VA] Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989777 4.7 5.3 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03803628 < 0.06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (5)
DateValueMinMax
2026-07-09 16:26 1.109 10
2026-07-09 16:27 0.994 10
2026-07-09 16:28 0.968 10
2026-07-09 16:29 0.957 10
2026-07-09 16:30 0.957 10