DateMeasurement IDID recordArticleResult
2025-09-05 10:36 25805 638926581409207561-2140 S0001055 Fail View
2025-11-06 17:05 40606 638980418679570215-1353 S0001055 Fail View
2026-02-05 07:21 51256 639058728299878839-1526 S0001055 Fail View
2026-02-05 07:22 51257 639058728862677151-7097 S0001055 Fail View
2026-02-05 07:23 51258 639058729599788506-4143 S0001055 Fail View
2026-02-05 07:24 51259 639058730425887156-7667 S0001055 Fail View
2026-02-05 07:26 51260 639058731263705843-1505 S0001055 Fail View
2026-02-05 07:27 51261 639058732030283922-5047 S0001055 Pass View
2026-07-09 16:10 77793 639192101948948068-2599 S0001055 Pass View

Test 25805

Result
Fail
Date
2025-09-05 10:36
Article
S0001055
ID record
638926581409207561-2140
ID production
49348
Temperature
28.02
Humidity
45.66
Test duration
55
Error ID
399
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 49348 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 28.02 Pass
0.4 Uložení vlhkosti okolí 45.66 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.690029009 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1005.29395 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001377503 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02439238 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9609649 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.996274 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8656589 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98712404 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.29971544 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.29972612 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.67076514 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.66315253 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.66736938 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.561032873 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7796731 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02514972 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 1.955404 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6169433 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2011735 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.56881149 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.0251173 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3865 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2039 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4086 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 1979 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2012 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 1977 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4086 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2036 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.29539431 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00347078561 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.29678079 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00345337248 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.29533797 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00356824433 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.29551143 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00345648287 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 75 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1706 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.1706 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0032375 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1645 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1668 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0104657 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1626 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1687 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0080169 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.00584153225 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2265 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2266 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2261 Pass
20.0.5 Analysis: VA VA[2265] 2210 2340 Pass
20.0.6 Analysis: VB VB[2266] 2210 2340 Pass
20.0.7 Analysis: VC VC[2261] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989683 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2433 2430[VA] 2530[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2099 2001[VB] 2101[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2261 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03772978 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989918 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2097 2000[VA] 2100[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2432 2431[VB] 2531[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2261 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989877 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2433 2430[VA] 2530[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2269 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2096 1996[VC] 2096[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.9899 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2097 2000[VA] 2100[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2264 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2425 2426[VC] 2526[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2026-07-09 16:10 1.078 10