Serial 001791569

Tests8
Approved2
Failures6

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-04 15:01 101 638610516788484721-1751 S0001055 Fail View
2024-09-04 15:21 102 638610528905440094-1406 S0001055 Fail View
2024-09-23 09:20 520 638626727960579126-6443 S0001055 Fail View
2024-09-24 14:37 555 638627782107105054-2811 S0001055 Fail View
2024-12-05 15:01 5417 638690040871512392-8265 S0001055 Fail View
2024-12-05 15:33 5418 638690060117435837-9406 S0001055 Fail View
2025-09-05 11:03 25769 638926597548983250-7725 S0001055 Pass View
2026-01-16 05:22 48478 639041376809295382-9172 S0001055 Pass View

Test 25769

Result
Pass
Date
2025-09-05 11:03
Article
S0001055
ID record
638926597548983250-7725
ID production
49267
Temperature
27.83
Humidity
45.87
Test duration
62
Error ID
Error text

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 49267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 27.83 Pass
0.4 Uložení vlhkosti okolí 45.87 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.726819862 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1000.7692 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.00122132 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02461044 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9609841 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9964857 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8313155 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.99743775 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.31250713 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.31251537 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.67813733 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.6749993 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.67463757 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.521705719 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7425101 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02446014 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.102729 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5958261 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2765472 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.62225787 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02541196 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3834 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2028 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2026 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2013 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2025 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2023 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30832736 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00347165336 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30961691 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00357514723 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.3081432 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.0035673062 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30828062 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.0034791169 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 54 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.0684 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.0669 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.010078 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.0646 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.0665 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0011504 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.0628 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.0665 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.012143 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.000937926661 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2258 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2255 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2261 Pass
20.0.5 Analysis: VA VA[2258] 2210 2340 Pass
20.0.6 Analysis: VB VB[2255] 2210 2340 Pass
20.0.7 Analysis: VC VC[2261] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989857 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2433 2423[VA] 2523[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2086 1990[VB] 2090[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2261 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03821307 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989873 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2082 1993[VA] 2093[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2424 2420[VB] 2520[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2261 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989703 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2433 2423[VA] 2523[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2258 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2090 1996[VC] 2096[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989964 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2082 1993[VA] 2093[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2253 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2431 2426[VC] 2526[VC] Pass
20.5.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989799 4.7 5.3 Pass
20.5.2 TestSW: [ADC_PA0] sense A 2259 2210 2340 Pass
20.5.3 TestSW: [ADC_PA1] sense B 2426 2420[VB] 2520[VB] Pass
20.5.4 TestSW: [ADC_PA2] sense C 2090 1996[VC] 2096[VC] Pass
20.6.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989902 4.7 5.3 Pass
20.6.2 TestSW: [ADC_PA0] sense A 2258 2210 2340 Pass
20.6.3 TestSW: [ADC_PA1] sense B 2083 1990[VB] 2090[VB] Pass
20.6.4 TestSW: [ADC_PA2] sense C 2431 2426[VC] 2526[VC] Pass
23.1 DMM: měření RMS(TP49/TP67) 0.572395949 0.1 1.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2026-01-16 05:22 0.859 10