Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001791563

Tests16
Approved0
Failures16

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-09 09:25 314 638614634765678713-9201 S0001055 Fail View
2024-09-09 09:32 315 638614639338165882-7606 S0001055 Fail View
2024-09-09 09:54 316 638614651878217729-1702 S0001055 Fail View
2024-09-09 10:08 317 638614660586133595-5269 S0001055 Fail View
2024-09-23 09:11 516 638626722510725967-2507 S0001055 Fail View
2024-09-24 14:51 553 638627790017530403-2609 S0001055 Fail View
2024-12-05 15:04 5413 638690042408951515-5537 S0001055 Fail View
2024-12-05 15:26 5414 638690055457018875-4409 S0001055 Fail View
2025-09-05 11:25 25767 638926610640555499-9837 S0001055 Fail View
2025-11-06 17:28 40591 638980432573811170-4849 S0001055 Fail View
2026-07-09 14:51 77747 639192054299298921-6972 S0001055 Fail View
2026-07-09 14:52 77748 639192054931394286-5596 S0001055 Fail View
2026-08-11 04:38 81268 639220198731292262-1414 S0001055 Fail View
2026-08-11 04:39 81269 639220199356987223-4396 S0001055 Fail View
2026-09-23 05:24 86091 639257378295154043-1674 S0001055 Fail View
2026-09-23 05:50 86106 639257393671081066-5914 S0001055 Fail View

Test 25767

Result
Fail
Date
2025-09-05 11:25
Article
S0001055
ID record
638926610640555499-9837
ID production
49267
Temperature
27.53
Humidity
46.83
Test duration
54
Error ID
359
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 49267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 27.53 Pass
0.4 Uložení vlhkosti okolí 46.83 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.776515358 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999.331067 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0009001133 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02427745 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9688204 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9968947 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.9050043 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98646999 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.3089547 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30896321 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66768206 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.664052 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.66551777 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.504256017 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.8291056 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02554459 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.022495 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6100529 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2331766 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.58247844 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02557112 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3835 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2025 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2023 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2024 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2027 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30459754 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00355975291 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30591387 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00350791641 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30442285 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00370519312 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30457657 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.0035672058 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 52 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.0703 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.0646 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0090962 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.0628 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.0665 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0003965 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.0628 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.0669 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0076058 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.000471598812 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2256 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2255 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2256 Pass
20.0.5 Analysis: VA VA[2256] 2210 2340 Pass
20.0.6 Analysis: VB VB[2255] 2210 2340 Pass
20.0.7 Analysis: VC VC[2256] 2210 2340 Pass
20.1.3 TestSW: [ADC_PA1] sense B 2092 1990[VB] 2090[VB] Fail
20.1.2 TestSW: [ADC_PA0] sense A 2423 2421[VA] 2521[VA] Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989791 4.7 5.3 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03802447 < 0.06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (6)
DateValueMinMax
2026-07-09 14:51 0.98 10
2026-07-09 14:52 0.973 10
2026-08-11 04:38 0.79 10
2026-08-11 04:39 0.778 10
2026-09-23 05:24 0.834 10
2026-09-23 05:50 0.801 10