Serial 001791562

Tests11
Approved1
Failures10

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-09 09:17 311 638614630285353655-2578 S0001055 Fail View
2024-09-09 09:56 312 638614653393638359-1604 S0001055 Fail View
2024-09-09 10:05 313 638614658961195391-7476 S0001055 Fail View
2024-09-23 09:19 515 638626727057512382-3969 S0001055 Fail View
2024-12-05 14:59 5411 638690039139202765-8350 S0001055 Fail View
2024-12-05 15:30 5412 638690057708714188-6156 S0001055 Fail View
2025-09-05 11:23 25766 638926609805697372-8443 S0001055 Fail View
2025-11-06 17:39 40590 638980439426395464-4368 S0001055 Fail View
2026-07-09 15:15 77762 639192068747640023-1240 S0001055 Fail View
2026-07-09 15:16 77763 639192069420887805-8903 S0001055 Fail View
2026-07-09 15:17 77764 639192070059883446-2385 S0001055 Pass View

Test 25766

Result
Fail
Date
2025-09-05 11:23
Article
S0001055
ID record
638926609805697372-8443
ID production
49267
Temperature
27.53
Humidity
46.83
Test duration
57
Error ID
399
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 49267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 27.53 Pass
0.4 Uložení vlhkosti okolí 46.83 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.686042505 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999.721623 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0009384223 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02420967 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9687839 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9971062 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.9488889 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98100399 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30882678 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30882394 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66277958 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.65912097 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.65878041 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.517270823 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.8626651 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02591 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.110662 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.6111461 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2882304 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.59474529 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02594831 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3846 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2025 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2025 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2028 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2029 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30439917 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.0035360783 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30560733 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00352671333 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30423778 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00367049099 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30437985 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00354833872 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 54 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.0778 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.0759 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0061519 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.0726 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.0778 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0101487 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.0722 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.0764 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0006463 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.00277119151 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2259 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2257 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2259 Pass
20.0.5 Analysis: VA VA[2259] 2210 2340 Pass
20.0.6 Analysis: VB VB[2257] 2210 2340 Pass
20.0.7 Analysis: VC VC[2259] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00851 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989851 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2428 2424[VA] 2524[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2089 1992[VB] 2092[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2260 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03818065 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989883 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2091 1994[VA] 2094[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2424 2422[VB] 2522[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2259 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989722 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2427 2424[VA] 2524[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2260 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2094 1994[VC] 2094[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989944 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2091 1994[VA] 2094[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2254 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2423 2424[VC] 2524[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-09 15:15 1.011 10
2026-07-09 15:16 0.971 10
2026-07-09 15:17 0.965 10