Serial 001791554

Tests10
Approved1
Failures9

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-09 06:05 300 638614515003811653-2194 S0001055 Fail View
2024-09-09 06:45 301 638614538659523728-5364 S0001055 Fail View
2024-09-23 09:05 512 638626718944731491-1685 S0001055 Fail View
2024-12-05 15:16 5405 638690049161350754-3563 S0001055 Fail View
2024-12-05 15:29 5406 638690057022146229-3694 S0001055 Fail View
2025-09-05 11:22 25763 638926608887503626-5997 S0001055 Fail View
2025-11-06 17:38 40587 638980438864132549-2310 S0001055 Fail View
2026-07-09 15:19 77765 639192071045395878-6412 S0001055 Fail View
2026-07-09 15:20 77766 639192071682686087-8706 S0001055 Fail View
2026-07-09 15:21 77767 639192072331082290-1031 S0001055 Pass View

Test 25763

Result
Fail
Date
2025-09-05 11:22
Article
S0001055
ID record
638926608887503626-5997
ID production
49267
Temperature
27.53
Humidity
46.83
Test duration
57
Error ID
399
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 49267 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 27.53 Pass
0.4 Uložení vlhkosti okolí 46.83 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.682146998 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1000.77018 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0009796781 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02422146 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9718833 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9970394 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.9160393 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98547418 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30290947 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30290889 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.6670016 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.66410144 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.66375743 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.520347217 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.834062 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02560353 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.094747 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5865209 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2833208 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.61240159 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02564479 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3843 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2028 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2026 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2013 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2022 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2025 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.29836138 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00355715898 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.29970365 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00354039885 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.29818428 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00367525 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.29834385 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00356617956 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 52 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.0929 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.0891 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0073553 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.0854 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.091 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0039808 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.0854 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.0891 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.008922 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.000199084361 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2258 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2254 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2265 Pass
20.0.5 Analysis: VA VA[2258] 2210 2340 Pass
20.0.6 Analysis: VB VB[2254] 2210 2340 Pass
20.0.7 Analysis: VC VC[2265] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989853 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2427 2423[VA] 2523[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2089 1989[VB] 2089[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2265 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03817184 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989995 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2088 1993[VA] 2093[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2419 2419[VB] 2519[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2265 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.98978 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2427 2423[VA] 2523[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2258 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2100 2000[VC] 2100[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989886 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2088 1993[VA] 2093[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2252 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2429 2430[VC] 2530[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-09 15:19 0.994 10
2026-07-09 15:20 0.958 10
2026-07-09 15:21 0.953 10