Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001006368

Tests10
Approved1
Failures9

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-23 08:12 494 638626687032303020-6859 S0001055 Fail View
2024-12-05 14:19 5386 638690015797588335-6715 S0001055 Fail View
2024-12-05 14:21 5387 638690016936685380-1117 S0001055 Fail View
2025-09-05 06:59 25757 638926451948312103-4812 S0001055 Fail View
2025-09-05 09:10 25758 638926530394086491-5949 S0001055 Fail View
2025-09-05 09:25 25759 638926538509742592-1745 S0001055 Pass View
2026-01-15 12:54 48455 639040784810980424-5553 S0001055 Fail View
2026-01-15 12:55 48456 639040784999098406-4338 S0001055 Fail View
2026-07-09 17:22 77830 639192145533491736-5673 S0001055 Fail View
2026-07-09 17:24 77831 639192146301414768-7242 S0001055 Fail View

Test 25759

Result
Pass
Date
2025-09-05 09:25
Article
S0001055
ID record
638926538509742592-1745
ID production
49265
Temperature
28.04
Humidity
44.62
Test duration
63
Error ID
Error text

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 49265 Pass
0.2 Uložení ID obsluhy 1332 Pass
0.3 Uložení teploty okolí 28.04 Pass
0.4 Uložení vlhkosti okolí 44.62 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.732418522 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1000.89223 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.000366734 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02424798 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9611748 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9953696 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8421841 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.9760068 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.29877411 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.29877435 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.65819278 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.65575614 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.65524894 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.51535058 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7589752 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02444542 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.157725 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5661013 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3053976 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.61131709 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02570372 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3858 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2024 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2024 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2012 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4086 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2024 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4086 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2025 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.29451238 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00349359368 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.29574966 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00348863948 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.29440065 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00360776431 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.29451858 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00351020167 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 53 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1494 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.1498 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0081114 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1456 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1475 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0063492 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1419 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1475 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0088261 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.000915839876 < 0.5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2263 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2259 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2261 Pass
20.0.5 Analysis: VA VA[2263] 2210 2340 Pass
20.0.6 Analysis: VB VB[2259] 2210 2340 Pass
20.0.7 Analysis: VC VC[2261] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989737 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2435 2428[VA] 2528[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2087 1994[VB] 2094[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2261 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03810111 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989684 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2089 1998[VA] 2098[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2431 2424[VB] 2524[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2261 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989748 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2436 2428[VA] 2528[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2262 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2091 1996[VC] 2096[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989739 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2089 1998[VA] 2098[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2257 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2430 2426[VC] 2526[VC] Pass
20.5.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989583 4.7 5.3 Pass
20.5.2 TestSW: [ADC_PA0] sense A 2263 2210 2340 Pass
20.5.3 TestSW: [ADC_PA1] sense B 2433 2424[VB] 2524[VB] Pass
20.5.4 TestSW: [ADC_PA2] sense C 2091 1996[VC] 2096[VC] Pass
20.6.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989664 4.7 5.3 Pass
20.6.2 TestSW: [ADC_PA0] sense A 2262 2210 2340 Pass
20.6.3 TestSW: [ADC_PA1] sense B 2084 1994[VB] 2094[VB] Pass
20.6.4 TestSW: [ADC_PA2] sense C 2430 2426[VC] 2526[VC] Pass
23.1 DMM: měření RMS(TP49/TP67) 0.159498794 0.1 1.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-07-09 17:22 1.555 10
2026-07-09 17:24 1.362 10