Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001417062

Tests8
Approved4
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-10-23 13:57 2490 638652806989847185-4861 SB-VBB-050_P04 Pass View
2024-10-23 14:21 2491 638652820923611171-8211 SB-VBB-050_P04 Pass View
2024-10-23 14:59 2492 638652851294466642-1594 SB-VBB-050_P04 Fail View
2024-10-24 09:02 2502 638653493455170162-6634 SB-VBB-050_P04 Pass View
2024-10-24 11:09 2503 638653577092570075-5601 SB-VBB-050_P04 Fail View
2024-10-24 11:10 2504 638653577926942130-2010 SB-VBB-050_P04 Fail View
2024-10-24 11:11 2505 638653578739459912-2521 SB-VBB-050_P04 Fail View
2025-02-19 09:13 14530 638755488490320094-7526 SB-VBB-050_P04 Pass View

Test 2505

Result
Fail
Date
2024-10-24 11:11
Article
SB-VBB-050_P04
ID record
638653578739459912-2521
ID production
48295
Temperature
25,9
Humidity
32,11
Test duration
3
Error ID
76
Error text
DMM: Měření napětí: +3V3_PERM (TP41/TP65)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 48295 Pass
0.2 Uložení ID obsluhy 0446 Pass
0.3 Uložení teploty okolí 25,9 Pass
0.4 Uložení vlhkosti okolí 32,11 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) SB-VBB-050_P04 Pass
0.6 DMM: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.7 NZ3: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.8 EL: Status? 0000000000000000 xxxxxxxxx000000x Pass
1.1 NZ3: Měření napětí: Zkrat? 2,315464 < 4,9 Pass
1.2 DMM: Měření napětí: +3V3_PERM (TP41/TP65) 2,72515319 3,25 3,35 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2025-02-19 09:13 48295