Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001417014

Tests8
Approved5
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-10-23 14:53 2488 638652847434835954-6510 SB-VBB-050_P04 Fail View
2024-10-23 16:05 2489 638652883631524882-9047 SB-VBB-050_P04 Pass View
2024-10-24 11:13 2500 638653580207228766-8212 SB-VBB-050_P04 Fail View
2024-10-24 11:24 2501 638653584427986728-1299 SB-VBB-050_P04 Pass View
2025-02-19 09:32 14526 638755499708390088-5364 SB-VBB-050_P04 Pass View
2025-09-10 12:21 26011 638930964302623928-2688 SB-VBB-050_P04 Pass View
2025-09-11 10:18 26312 638931754149135409-2486 SB-VBB-050_P04 Pass View
2025-09-11 10:26 26313 638931759006469808-6583 SB-VBB-050_P04 Fail View

Test 2500

Result
Fail
Date
2024-10-24 11:13
Article
SB-VBB-050_P04
ID record
638653580207228766-8212
ID production
48295
Temperature
25,9
Humidity
32,11
Test duration
3
Error ID
76
Error text
DMM: Měření napětí: +3V3_PERM (TP41/TP65)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 48295 Pass
0.2 Uložení ID obsluhy 0446 Pass
0.3 Uložení teploty okolí 25,9 Pass
0.4 Uložení vlhkosti okolí 32,11 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) SB-VBB-050_P04 Pass
0.6 DMM: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.7 NZ3: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.8 EL: Status? 0000000000000000 xxxxxxxxx000000x Pass
1.1 NZ3: Měření napětí: Zkrat? 2,009784 < 4,9 Pass
1.2 DMM: Měření napětí: +3V3_PERM (TP41/TP65) 2,73075965 3,25 3,35 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2025-09-10 12:21 48295
2025-09-11 10:18 48295
2025-09-11 10:26 48295