Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000138

Tests4
Approved1
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-12-12 14:10 23690 639011453997997477-3401 S0003591 Fail View
2025-12-12 14:11 23691 639011454491324974-9865 S0003591 Fail View
2025-12-12 14:12 23692 639011455030988360-3110 S0003591 Fail View
2025-12-12 14:13 23693 639011455553763957-7072 S0003591 Pass View

Test 23691

Result
Fail
Date
2025-12-12 14:11
Article
S0003591
ID record
639011454491324974-9865
ID production
Temperature
Humidity
Test duration
28
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5615.97367 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 998.505967 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.433018918 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.63075698 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1456214.8 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.18907314 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29309243 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28597666 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.28392998 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79746603 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9840242 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0110488 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9482468 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2025-12-12 14:10 998.59 950 1050
2025-12-12 14:11 998.506 950 1050
2025-12-12 14:12 998.506 950 1050
2025-12-12 14:13 998.437 950 1050