DateMeasurement IDID recordArticleResult
2025-12-12 13:24 23651 639011426440085860-7080 S0003591 Fail View
2025-12-12 13:25 23652 639011426909479135-7773 S0003591 Fail View
2025-12-12 13:26 23653 639011427452647174-1676 S0003591 Pass View

Test 23652

Result
Fail
Date
2025-12-12 13:25
Article
S0003591
ID record
639011426909479135-7773
ID production
Temperature
Humidity
Test duration
28
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5604.78211 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1002.52212 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.656823154 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.643626387 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1405127.83 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.13521158 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29537122 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28837647 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.2939481 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79780622 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9945292 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.00834146 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9199877 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2025-12-12 13:24 1002.557 950 1050
2025-12-12 13:25 1002.522 950 1050
2025-12-12 13:26 1002.491 950 1050