Serial lookup
Search a serial number to see its full test history.
Serial C00000137
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-12-12 10:22 | 23493 | 639011317434676462-8386 | S0003591 | Fail | View |
| 2025-12-12 10:24 | 23494 | 639011317884186954-4652 | S0003591 | Pass | View |
Test 23494
- Result
- Pass
- Date
- 2025-12-12 10:24
- Article
- S0003591
- ID record
- 639011317884186954-4652
- ID production
- Temperature
- Humidity
- Test duration
- 53
- Error ID
- —
- Error text
- —
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 998.916582 | 950 | 1050 | Pass |
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5601.7245 | 5320 | 5880 | Pass |
| 1.2.1 | DMM: Měření odporu: F1 (TP9/TP8) | 0.63722912 | < | 2 | Pass |
| 1.2.2 | DMM: Měření odporu: F2 (TP10/TP11) | 0.50964319 | < | 2.5 | Pass |
| 1.2.3 | DMM: Měření odporu: R3+R4 (TP10/TP8) | 1366772.96 | 120000 | 1540000 | Pass |
| 2.2.1 | DMM: Měření napětí: +5V StepDown Output (TP2/TP13) | 5.14508848 | 4 | 6 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) | 3.29374323 | 2.64 | 3.96 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) | 3.28725043 | 2.64 | 3.96 | Pass |
| 2.2.4 | DMM: Měření napětí: +3V3 VDDA (TP2/TP22) | 3.29239435 | 2.64 | 3.96 | Pass |
| 2.2.5 | DMM: Měření napětí: +1V8 Audio (TP2/TP24) | 1.79934369 | 1.44 | 2.16 | Pass |
| 2.2.6 | DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) | 11.9946136 | 9.6 | 14.4 | Pass |
| 2.3.1 | AC1: Měření proudu: Kontrola odběru | 0.02388 | < | 0.12 | Pass |
| 2.3.2 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.956232 | 11.4 | 12.6 | Pass |
| 3.10.1 | TestSW: Audio Output test | 17843 | 1000 | 20000 | Pass |
| 3.2.1 | DMM: Měření frekvence: 1kHz (TP2/TP17) | 1000.01041 | 999.8 | 1000.2 | Pass |
| 3.3.2 | DMM: Měření proudu: LEDR (TP25/TP27) | 0.0343428668 | 0.015 | 0.05 | Pass |
| 3.3.6 | DMM: Měření proudu: LEDG (TP25/TP27) | 4.08496996E-08 | < | 0.0005 | Pass |
| 3.3.5 | DMM: Měření proudu: LEDG (TP25/TP27) | 0.0347271963 | 0.015 | 0.05 | Pass |
| 3.3.3 | DMM: Měření proudu: LEDR (TP25/TP27) | 4.47691855E-08 | < | 0.0005 | Pass |
| 3.3.1 | DMM: Měření proudu: LEDR (TP25/TP27) | 5.08103929E-08 | < | 0.0005 | Pass |
| 3.3.4 | DMM: Měření proudu: LEDG (TP25/TP27) | 4.14861289E-08 | < | 0.0005 | Pass |
| 3.4.1 | DMM: Měření proudu: (TP29/TP27) | 0.00097817496 | < | 0.0013 | Pass |
| 3.4.2 | DMM: Měření proudu: (TP34/TP27) | 0.000977505262 | < | 0.0013 | Pass |
| 3.5.1 | NZ3.1: Měření proudu: Kontrola odběru | 0.005124283 | < | 0.01 | Pass |
| 3.5.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.005059644 | < | 0.01 | Pass |
| 3.6.1 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) OPEN | 9.9E+37 | > | 1000000 | Pass |
| 3.6.2 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) SHORT | 0.306161206 | < | 1 | Pass |
| 3.6.3 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) OPEN | 9.9E+37 | > | 1000000 | Pass |
| 3.6.4 | DMM: Měření zkratu: RE6 - BE (TP45/TP44) OPEN | 9.9E+37 | > | 1000000 | Pass |
| 3.6.5 | DMM: Měření zkratu: RE6 - BE (TP45/TP44) SHORT | 0.298272856 | < | 1 | Pass |
| 3.6.6 | DMM: Měření zkratu: RE6 - BE (TP45/TP44) OPEN | 9.9E+37 | > | 1000000 | Pass |
| 3.7.1 | DMM: Měření zkratu: Audio (TP37/TP32) SHORT | 0.371314197 | < | 1 | Pass |
| 3.7.2 | DMM: Měření zkratu: Audio (TP37/TP33) SHORT | 0.358692837 | < | 1 | Pass |
| 3.7.3 | DMM: Měření zkratu: Audio (TP31/TP35) SHORT | 0.396088396 | < | 1 | Pass |
| 3.7.4 | DMM: Měření zkratu: Audio (TP30/TP36) SHORT | 0.367690336 | < | 1 | Pass |
| 3.9.1 | TestSW: Audio Output test | 13824 | 1000 | 20000 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-12-12 10:22 | 998.968 | 950 | 1050 |
| 2025-12-12 10:24 | 998.917 | 950 | 1050 |