Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000226

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-12-12 09:52 23472 639011299218858303-5728 S0003591 Fail View
2025-12-12 09:53 23473 639011299867613654-7335 S0003591 Fail View
2025-12-12 09:55 23474 639011300526379446-5244 S0003591 Pass View

Test 23473

Result
Fail
Date
2025-12-12 09:53
Article
S0003591
ID record
639011299867613654-7335
ID production
Temperature
Humidity
Test duration
16
Error ID
208
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5613.60706 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 999.964163 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.416073238 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.402988309 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1386363.86 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.20155255 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29477026 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28738173 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.28569096 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.800558 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.989895 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0112707 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9679833 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2025-12-12 09:52 1000.045 950 1050
2025-12-12 09:53 999.964 950 1050
2025-12-12 09:55 999.908 950 1050