Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C01000024

Tests5
Approved2
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-12-11 10:37 23135 639010462186804363-7042 S0003590 Fail View
2025-12-11 10:39 23136 639010462876604868-2449 S0003590 Pass View
2026-06-24 09:54 75877 639178916123003705-6032 S0003590 Fail View
2026-06-24 09:55 75878 639178916835782806-6022 S0003590 Fail View
2026-06-24 09:56 75879 639178917385791409-9552 S0003590 Pass View

Test 23135

Result
Fail
Date
2025-12-11 10:37
Article
S0003590
ID record
639010462186804363-7042
ID production
Temperature
Humidity
Test duration
31
Error ID
186
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5599.24509 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1001.58995 950 1050 Pass
1.2.1 Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) 0.424554 0 2 Pass
1.2.2 Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) 0.502259 0 2 Pass
1.2.3 Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) 421041.203714 400000 460000 Pass
2.2.1 DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) 3.28953408 3.1 3.4 Pass
2.2.2 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) 3.28337887 3.1 3.4 Pass
2.2.3 DMM: Měření napětí: +3V3 VDDA (TP2/TP24) 3.28877744 3.1 3.4 Pass
2.2.4 DMM: Měření napětí: +1V8 Audio (TP2/TP26) 1.79377698 1.74 1.86 Pass
2.3.1 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 12.0255283 11.7 12.3 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-06-24 09:54 1001.364 950 1050
2026-06-24 09:55 1001.304 950 1050
2026-06-24 09:56 1001.284 950 1050