Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C01000023

Tests6
Approved2
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-12-11 10:36 23134 639010461598735841-2711 S0003590 Fail View
2025-12-11 10:40 23137 639010463654344515-4579 S0003590 Pass View
2026-06-24 09:58 75880 639178918294869668-1615 S0003590 Fail View
2026-06-24 09:59 75881 639178919028899554-2988 S0003590 Fail View
2026-06-24 10:00 75882 639178919600292281-2132 S0003590 Fail View
2026-06-24 10:01 75883 639178920152435457-4661 S0003590 Pass View

Test 23134

Result
Fail
Date
2025-12-11 10:36
Article
S0003590
ID record
639010461598735841-2711
ID production
Temperature
Humidity
Test duration
38
Error ID
124
Error text
Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11)

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5615.34076 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 998.892106 950 1050 Pass
1.2.1 Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) 0.487173 0 2 Pass
1.2.2 Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) 5.811066 0 2 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-06-24 09:58 998.718 950 1050
2026-06-24 09:59 998.668 950 1050
2026-06-24 10:00 998.66 950 1050
2026-06-24 10:01 998.65 950 1050