Serial lookup
Search a serial number to see its full test history.
Serial C01000084
Tests3
Approved2
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-12-11 09:31 | 23089 | 639010422869583687-7145 | S0003590 | Fail | View |
| 2025-12-11 09:34 | 23090 | 639010423922921475-8496 | S0003590 | Pass | View |
| 2026-07-14 05:03 | 78231 | 639196021573890490-3534 | S0003590 | Pass | View |
Test 23089
- Result
- Fail
- Date
- 2025-12-11 09:31
- Article
- S0003590
- ID record
- 639010422869583687-7145
- ID production
- Temperature
- Humidity
- Test duration
- 31
- Error ID
- 186
- Error text
- Vyhodnocení programu: [testSW]
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5621.51444 | 5320 | 5880 | Pass |
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 998.265925 | 950 | 1050 | Pass |
| 1.2.1 | Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) | 0.628705 | 0 | 2 | Pass |
| 1.2.2 | Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) | 0.494081 | 0 | 2 | Pass |
| 1.2.3 | Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) | 420662.336 | 400000 | 460000 | Pass |
| 2.2.1 | DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) | 3.3038002 | 3.1 | 3.4 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) | 3.29833929 | 3.1 | 3.4 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 VDDA (TP2/TP24) | 3.30395987 | 3.1 | 3.4 | Pass |
| 2.2.4 | DMM: Měření napětí: +1V8 Audio (TP2/TP26) | 1.80027613 | 1.74 | 1.86 | Pass |
| 2.3.1 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.9961179 | 11.7 | 12.3 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-14 05:03 | 998.096 | 950 | 1050 |