Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000002

Tests4
Approved1
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-11-18 08:29 22816 638990513467933034-4076 S0003591 Fail View
2025-11-18 12:31 22927 638990658173893288-4926 S0003591 Fail View
2025-11-18 12:31 22928 638990658844231493-6849 S0003591 Fail View
2025-11-18 12:33 22929 638990659442866797-5561 S0003591 Pass View

Test 22928

Result
Fail
Date
2025-11-18 12:31
Article
S0003591
ID record
638990658844231493-6849
ID production
Temperature
Humidity
Test duration
25
Error ID
214
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5604.04005 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1001.07528 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.805702031 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.554879408 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1409827.31 1200000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.19461078 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29339898 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28620611 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.28440407 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79676082 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9896719 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0080803 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9266889 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2025-11-18 08:29 1001.139 950 1050
2025-11-18 12:31 1001.121 950 1050
2025-11-18 12:31 1001.075 950 1050
2025-11-18 12:33 1001.075 950 1050