Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000037

Tests4
Approved1
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-11-18 11:33 22921 638990623956874216-2543 S0003591 Fail View
2025-11-18 11:34 22922 638990624512194541-9743 S0003591 Fail View
2025-11-18 11:35 22923 638990625211532644-4179 S0003591 Fail View
2025-12-12 14:14 23694 639011456262486963-6119 S0003591 Pass View

Test 22921

Result
Fail
Date
2025-11-18 11:33
Article
S0003591
ID record
638990623956874216-2543
ID production
Temperature
Humidity
Test duration
23
Error ID
214
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5608.42662 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1001.57625 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.810404165 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.817266282 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1203589.55 1200000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.11321256 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29450458 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.29399521 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.29369148 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79740088 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9910129 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0216045 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.8886789 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2025-11-18 11:33 1001.576 950 1050
2025-11-18 11:34 1001.52 950 1050
2025-11-18 11:35 1001.472 950 1050
2025-12-12 14:14 1001.25 950 1050