DateMeasurement IDID recordArticleResult
2025-11-18 09:01 22840 638990532834630460-3677 S0003591 Fail View
2025-11-18 09:02 22841 638990533029777213-9548 S0003591 Fail View
2025-11-18 09:04 22842 638990534145616776-2094 S0003591 Pass View

Test 22841

Result
Fail
Date
2025-11-18 09:02
Article
S0003591
ID record
638990533029777213-9548
ID production
Temperature
Humidity
Test duration
23
Error ID
214
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5603.90114 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 999.245749 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.998557298 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.786808203 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1365324.34 1200000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.14656276 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29349881 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28718863 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.29208656 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79569373 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.996405 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.022479 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9931513 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2025-11-18 09:01 999.245 950 1050
2025-11-18 09:02 999.246 950 1050
2025-11-18 09:04 999.222 950 1050