Serial lookup
Search a serial number to see its full test history.
Serial C00000033
Tests3
Approved1
Failures2
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-11-18 08:55 | 22837 | 638990529331299411-3210 | S0003591 | Fail | View |
| 2025-11-18 08:56 | 22838 | 638990529524149830-5382 | S0003591 | Fail | View |
| 2025-11-18 08:59 | 22839 | 638990531185310231-1301 | S0003591 | Pass | View |
Test 22837
- Result
- Fail
- Date
- 2025-11-18 08:55
- Article
- S0003591
- ID record
- 638990529331299411-3210
- ID production
- Temperature
- Humidity
- Test duration
- 5
- Error ID
- 120
- Error text
- DMM: Měření odporu: R3+R4 (TP10/TP8)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5607.64564 | 5320 | 5880 | Pass |
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 999.944876 | 950 | 1050 | Pass |
| 1.2.1 | DMM: Měření odporu: F1 (TP9/TP8) | 0.589077469 | < | 2 | Pass |
| 1.2.2 | DMM: Měření odporu: F2 (TP10/TP11) | 0.846478137 | < | 2.5 | Pass |
| 1.2.3 | DMM: Měření odporu: R3+R4 (TP10/TP8) | 689050.096 | 1200000 | 1540000 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (3)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-11-18 08:55 | 999.945 | 950 | 1050 |
| 2025-11-18 08:56 | 999.958 | 950 | 1050 |
| 2025-11-18 08:59 | 999.894 | 950 | 1050 |