Serial C00000046

Tests4
Approved2
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-11-18 08:43 22827 638990521661134754-7037 S0003591 Fail View
2025-11-18 08:44 22828 638990522373618642-5270 S0003591 Fail View
2025-11-18 08:45 22829 638990522845913447-7405 S0003591 Pass View
2025-11-18 08:47 22830 638990523921491474-4112 S0003591 Pass View

Test 22828

Result
Fail
Date
2025-11-18 08:44
Article
S0003591
ID record
638990522373618642-5270
ID production
Temperature
Humidity
Test duration
14
Error ID
204
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5615.59241 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 998.454975 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.600582652 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.80208282 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1407741.24 1200000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.19962412 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.28927643 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28217691 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.28014034 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79907442 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9731286 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.00924569 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9268326 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2025-11-18 08:43 998.48 950 1050
2025-11-18 08:44 998.455 950 1050
2025-11-18 08:45 998.452 950 1050
2025-11-18 08:47 998.452 950 1050