Serial lookup
Search a serial number to see its full test history.
Serial C00000002
Tests4
Approved1
Failures3
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-11-18 08:29 | 22816 | 638990513467933034-4076 | S0003591 | Fail | View |
| 2025-11-18 12:31 | 22927 | 638990658173893288-4926 | S0003591 | Fail | View |
| 2025-11-18 12:31 | 22928 | 638990658844231493-6849 | S0003591 | Fail | View |
| 2025-11-18 12:33 | 22929 | 638990659442866797-5561 | S0003591 | Pass | View |
Test 22816
- Result
- Fail
- Date
- 2025-11-18 08:29
- Article
- S0003591
- ID record
- 638990513467933034-4076
- ID production
- Temperature
- Humidity
- Test duration
- 5
- Error ID
- 120
- Error text
- DMM: Měření odporu: R3+R4 (TP10/TP8)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5605.1153 | 5320 | 5880 | Pass |
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 1001.13862 | 950 | 1050 | Pass |
| 1.2.1 | DMM: Měření odporu: F1 (TP9/TP8) | 0.826263853 | < | 2 | Pass |
| 1.2.2 | DMM: Měření odporu: F2 (TP10/TP11) | 0.696343759 | < | 2.5 | Pass |
| 1.2.3 | DMM: Měření odporu: R3+R4 (TP10/TP8) | 690139.565 | 1200000 | 1540000 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (4)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-11-18 08:29 | 1001.139 | 950 | 1050 |
| 2025-11-18 12:31 | 1001.121 | 950 | 1050 |
| 2025-11-18 12:31 | 1001.075 | 950 | 1050 |
| 2025-11-18 12:33 | 1001.075 | 950 | 1050 |