Serial 000797152

Tests14
Approved1
Failures13

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-19 12:33 346 638623387300018643-6041 S0001055 Fail View
2024-09-19 12:41 347 638623392208302988-5790 S0001055 Fail View
2024-09-19 12:42 348 638623392950854439-6507 S0001055 Fail View
2024-12-05 14:32 5333 638690022816728924-1879 S0001055 Fail View
2024-12-05 14:39 5334 638690027102964199-6831 S0001055 Fail View
2025-07-16 11:29 22214 638882549124900138-9377 S0001055 Fail View
2025-07-16 11:30 22215 638882549876914365-8935 S0001055 Fail View
2025-07-16 11:32 22216 638882550717837208-7445 S0001055 Fail View
2025-07-16 11:34 22217 638882551977991212-6980 S0001055 Fail View
2025-07-16 11:35 22218 638882552795311921-6176 S0001055 Pass View
2025-11-06 16:54 40578 638980412336203268-1311 S0001055 Fail View
2026-07-09 16:50 77822 639192125584608437-3885 S0001055 Fail View
2026-07-09 16:51 77823 639192126238100578-2421 S0001055 Fail View
2026-07-09 16:52 77824 639192126896309818-4343 S0001055 Fail View

Test 22215

Result
Fail
Date
2025-07-16 11:30
Article
S0001055
ID record
638882549876914365-8935
ID production
46078
Temperature
28.88
Humidity
45.91
Test duration
60
Error ID
371
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 28.88 Pass
0.4 Uložení vlhkosti okolí 45.91 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.829479551 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999.737328 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0002724348 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.0240712 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9582458 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9976291 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8960128 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.01703268 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30458285 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30458102 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.69602732 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.69292943 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.69281379 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.498190264 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.8229512 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02513793 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.07079 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5974913 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3326885 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.63106947 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02490808 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3860 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2001 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4086 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 1999 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4086 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2008 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4086 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2007 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.3005377 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.0034353633 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30187165 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00342243032 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30033086 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00354700013 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.30047653 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00345299278 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 56 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1701 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.172 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0090817 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1668 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1706 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0075202 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1645 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1701 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0094404 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.00176908222 < 0.5 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2280 Pass
20.0.7 Analysis: VC VC[2280] 2210 2340 Pass
20.0.6 Analysis: VB VB[2270] 2210 2340 Pass
20.0.5 Analysis: VA VA[2271] 2210 2340 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2270 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2271 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989422 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2443 2436[VA] 2536[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2105 2005[VB] 2105[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2281 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03812763 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.98942 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2098 2006[VA] 2106[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2434 2435[VB] 2535[VB] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-09 16:50 1.025 10
2026-07-09 16:51 1.018 10
2026-07-09 16:52 0.991 10