Serial lookup
Search a serial number to see its full test history.
Serial 001714106
Tests4
Approved1
Failures3
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2024-10-21 06:04 | 2162 | 638650802849170017-3750 | S0000608 | Fail | View |
| 2024-10-21 06:04 | 2163 | 638650802916951003-8844 | S0000608 | Fail | View |
| 2024-10-21 06:04 | 2164 | 638650802982961440-7697 | S0000608 | Fail | View |
| 2024-10-21 15:21 | 2165 | 638651136160826395-7803 | S0000608 | Pass | View |
Test 2162
- Result
- Fail
- Date
- 2024-10-21 06:04
- Article
- S0000608
- ID record
- 638650802849170017-3750
- ID production
- 50069
- Temperature
- 24,09
- Humidity
- 35,69
- Test duration
- 1
- Error ID
- 57
- Error text
- DMM: Kontrola hodnoty Odporu (TP2/TP3)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 50069 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0313 | Pass | ||
| 0.3 | Uložení teploty okolí | 24,09 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 35,69 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000608 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 1,09659423 | -1 | 1 | Fail |
Measurements over time
No plottable values for this measurement.
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2024-10-21 15:21 | — | — | — |