Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001856840

Tests7
Approved1
Failures6

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-07-08 15:37 21342 638875786242975527-2370 S0000608 Fail View
2025-07-08 15:38 21343 638875786989920118-5785 S0000608 Fail View
2025-07-08 15:51 21344 638875794930012587-6309 S0000608 Fail View
2025-07-08 19:51 21345 638875938850305130-9162 S0000608 Fail View
2025-07-08 19:51 21346 638875938992276250-1696 S0000608 Fail View
2025-07-23 14:04 22592 638888690812410100-5874 S0000608 Fail View
2025-11-04 07:53 40209 638978359150112115-8889 S0000608 Pass View

Test 21343

Result
Fail
Date
2025-07-08 15:38
Article
S0000608
ID record
638875786989920118-5785
ID production
53452
Temperature
28.18
Humidity
40.27
Test duration
7
Error ID
91
Error text
DMM: Kontrola hodnoty napětí (TP19/TP17,18)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 53452 Pass
0.2 Uložení ID obsluhy 1358 Pass
0.3 Uložení teploty okolí 28.18 Pass
0.4 Uložení vlhkosti okolí 40.27 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0000608 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP2/TP3) 2.22857604 -1 5 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP4/TP3) 5108.45005 5000 5200 Pass
1.3 DMM: Kontrola hodnoty Odporu (TP27/TP17,18) 10171.1183 9000 11000 Pass
2.1 DMM: Kontrola hodnoty Odporu (TP8/TP10) 1069.68056 1012 1120 Pass
4.1 NZ1: Odběr proudu ze zdroje (TP6/TP17,18) 0.004076409 0.0025 0.006 Pass
4.2 DMM: Kontrola hodnoty napětí (TP5/TP17,18) 11.9963349 11.9 12.1 Pass
4.3 DMM: Kontrola hodnoty napětí (TP19/TP17,18) 5.10465562 4.9 5.1 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2025-11-04 07:53 1856840