Serial lookup
Search a serial number to see its full test history.
Serial 001856765
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-07-08 18:26 | 21281 | 638875887620974420-9416 | S0000608 | Fail | View |
| 2025-07-08 18:27 | 21282 | 638875887767923667-8161 | S0000608 | Pass | View |
Test 21281
- Result
- Fail
- Date
- 2025-07-08 18:26
- Article
- S0000608
- ID record
- 638875887620974420-9416
- ID production
- 53452
- Temperature
- 28.45
- Humidity
- 37.87
- Test duration
- 6
- Error ID
- 85
- Error text
- NZ1: Odběr proudu ze zdroje (TP6/TP17,18)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 53452 | Pass | ||
| 0.2 | Uložení ID obsluhy | 1358 | Pass | ||
| 0.3 | Uložení teploty okolí | 28.45 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 37.87 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000608 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 2.16855257 | -1 | 5 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 5092.0897 | 5000 | 5200 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP27/TP17,18) | 10194.9242 | 9000 | 11000 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP8/TP10) | 1064.16564 | 1012 | 1120 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP6/TP17,18) | 2.723677E-05 | 0.0025 | 0.006 | Fail |
Measurements over time
No plottable values for this measurement.
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-07-08 18:27 | — | — | — |