Serial 001739217
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-07-04 07:46 | 21149 | 638872047089697476-6491 | S0003074 | Fail | View |
| 2025-07-04 11:33 | 21150 | 638872183392241332-7254 | S0003074 | Pass | View |
Test 21150
- Result
- Pass
- Date
- 2025-07-04 11:33
- Article
- S0003074
- ID record
- 638872183392241332-7254
- ID production
- 52071
- Temperature
- 28.46
- Humidity
- 32.71
- Test duration
- 65
- Error ID
- —
- Error text
- —
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.3 | Uložení teploty okolí | 28.46 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 32.71 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0003074 | Pass | ||
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 0.121965933 | 5.9 | 6.3 | Fail |
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 6.1028852 | 5.9 | 6.3 | Pass |
| 1.1 | DMM: Měření proudu: (TP100/TP101) změřít proud naprázdno | 0.000140641081 | 8E-05 | 0.00017 | Pass |
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 5.97030967 | 5.8 | 6.3 | Pass |
| 1.1 | DMM: Měření napětí: (TP8/TP4) | 3.41758658 | 2.6 | 3.6 | Pass |
| 1.1 | DMM: Měření napětí: (TP6/TP4) | 8.7135812 | 8.6 | 9 | Pass |
| 1.1 | DMM: Měření proudu: (TP100/TP101) změřít proud naprázdno | 0.000136520676 | 0.0001 | 0.0002 | Pass |
| 1.1 | DMM: Měření napětí: (TP6/TP4) | 8.75292659 | 8.6 | 9 | Pass |
| 9.2 | EL1.1: TP2/TP5 -> Current? | 0.4999463 | 0.475 | 0.525 | Pass |
| 9.2 | EL1.1: TP2/TP5 -> Current? | 0.4998872 | 0.475 | 0.525 | Pass |