Serial lookup
Search a serial number to see its full test history.
Serial 001739217
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-07-04 07:46 | 21149 | 638872047089697476-6491 | S0003074 | Fail | View |
| 2025-07-04 11:33 | 21150 | 638872183392241332-7254 | S0003074 | Pass | View |
Test 21149
- Result
- Fail
- Date
- 2025-07-04 07:46
- Article
- S0003074
- ID record
- 638872047089697476-6491
- ID production
- 52071
- Temperature
- 28.39
- Humidity
- 38.82
- Test duration
- 62
- Error ID
- 153
- Error text
- DMM: Měření napětí: (TP6/TP4)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.3 | Uložení teploty okolí | 28.39 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 38.82 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0003074 | Pass | ||
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 0.131706512 | 5.9 | 6.3 | Fail |
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 6.09922454 | 5.9 | 6.3 | Pass |
| 1.1 | DMM: Měření proudu: (TP100/TP101) změřít proud naprázdno | 0.000103582984 | 8E-05 | 0.00017 | Pass |
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 5.97580079 | 5.8 | 6.3 | Pass |
| 1.1 | DMM: Měření napětí: (TP8/TP4) | 3.41277194 | 2.6 | 3.6 | Pass |
| 1.1 | DMM: Měření napětí: (TP6/TP4) | 8.59731983 | 8.6 | 9 | Fail |
| 9.2 | EL1.1: TP2/TP5 -> Current? | 0.4999138 | 0.475 | 0.525 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-07-04 07:46 | 28.39 | — | — |
| 2025-07-04 11:33 | 28.46 | — | — |