Serial lookup
Search a serial number to see its full test history.
Serial 001739230
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-07-03 14:11 | 21009 | 638871414460699722-6644 | S0003074 | Fail | View |
| 2025-07-04 11:48 | 21160 | 638872192494384285-8048 | S0003074 | Pass | View |
Test 21009
- Result
- Fail
- Date
- 2025-07-03 14:11
- Article
- S0003074
- ID record
- 638871414460699722-6644
- ID production
- 52071
- Temperature
- 28.49
- Humidity
- 48.09
- Test duration
- 63
- Error ID
- 153
- Error text
- DMM: Měření napětí: (TP6/TP4)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.3 | Uložení teploty okolí | 28.49 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 48.09 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0003074 | Pass | ||
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 0.17964733 | 5.9 | 6.3 | Fail |
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 6.06977284 | 5.9 | 6.3 | Pass |
| 1.1 | DMM: Měření proudu: (TP100/TP101) změřít proud naprázdno | 0.000126881943 | 8E-05 | 0.00017 | Pass |
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 5.95767385 | 5.8 | 6.3 | Pass |
| 1.1 | DMM: Měření napětí: (TP8/TP4) | 3.33829787 | 2.6 | 3.6 | Pass |
| 1.1 | DMM: Měření napětí: (TP6/TP4) | 8.57249875 | 8.6 | 9 | Fail |
| 9.2 | EL1.1: TP2/TP5 -> Current? | 0.4999506 | 0.475 | 0.525 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-07-03 14:11 | 28.49 | — | — |
| 2025-07-04 11:48 | 28.58 | — | — |