| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-07-03 10:06 | 20954 | 638871267475689391-2319 | S0003074 | Fail | View |
| 2025-07-04 11:46 | 21130 | 638872190987992571-6704 | S0003074 | Pass | View |
Test 20954
- Result
- Fail
- Date
- 2025-07-03 10:06
- Article
- S0003074
- ID record
- 638871267475689391-2319
- ID production
- 52071
- Temperature
- 29.91
- Humidity
- 42.92
- Test duration
- 62
- Error ID
- 153
- Error text
- DMM: Měření napětí: (TP6/TP4)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.3 | Uložení teploty okolí | 29.91 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 42.92 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0003074 | Pass | ||
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 0.124434339 | 5.9 | 6.3 | Fail |
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 6.13519258 | 5.9 | 6.3 | Pass |
| 1.1 | DMM: Měření proudu: (TP100/TP101) změřít proud naprázdno | 0.000143668852 | 8E-05 | 0.00017 | Pass |
| 1.1 | DMM: Měření napětí: (TP2/TP4) | 6.01338958 | 5.8 | 6.3 | Pass |
| 1.1 | DMM: Měření napětí: (TP8/TP4) | 3.35612399 | 2.6 | 3.6 | Pass |
| 1.1 | DMM: Měření napětí: (TP6/TP4) | 9.03444069 | 8.6 | 9 | Fail |
| 9.2 | EL1.1: TP2/TP5 -> Current? | 0.4999056 | 0.475 | 0.525 | Pass |