Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001607498

Tests6
Approved2
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-07-02 13:38 20787 638870531133165289-2080 S0000174 Fail View
2025-07-02 13:44 20788 638870534368473411-9138 S0000174 Fail View
2025-07-02 13:44 20789 638870534514823267-7600 S0000174 Fail View
2025-07-03 05:59 20943 638871119159798897-6534 S0000174 Pass View
2025-11-19 21:00 43163 638991792450827435-2060 S0004028 Fail View
2025-11-19 21:02 43164 638991792704015841-7725 S0004028 Pass View

Test 20787

Result
Fail
Date
2025-07-02 13:38
Article
S0000174
ID record
638870531133165289-2080
ID production
52061
Temperature
30.97
Humidity
34.45
Test duration
5
Error ID
94
Error text
DMM: Kontrola hodnoty napětí (TP22/TP25,26)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 52061 Pass
0.2 Uložení ID obsluhy 0736 Pass
0.3 Uložení teploty okolí 30.97 Pass
0.4 Uložení vlhkosti okolí 34.45 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0000174 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP2/TP3) 999.43042 900 1100 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP4/TP3) 3308.19859 3200 3400 Pass
1.3 DMM: Kontrola hodnoty Odporu (TP48/TP25,26) 997.854171 900 1100 Pass
1.4 DMM: Kontrola hodnoty Odporu (TP13/TP25,26) 10060.2558 9500 10500 Pass
2.1 DMM: Kontrola hodnoty Odporu (TP36/TP37) 1068.37442 1012 1120 Pass
2.2 DMM: Kontrola hodnoty Odporu (TP40/TP41) 1039.48805 1012 1120 Pass
4.0 DMM: Kontrola hodnoty napětí (TP22/TP25,26) -0.752841061 -0.75 -0.65 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2025-11-19 21:00 1607498