Serial 001607470
Tests4
Approved2
Failures2
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-07-02 13:09 | 20782 | 638870513464613419-3266 | S0000174 | Fail | View |
| 2025-07-02 13:18 | 20783 | 638870519325460266-1644 | S0000174 | Fail | View |
| 2025-07-02 13:27 | 20784 | 638870523635808113-1896 | S0000174 | Pass | View |
| 2025-11-19 21:30 | 43160 | 638991809802966496-1812 | S0004028 | Pass | View |
Test 20784
- Result
- Pass
- Date
- 2025-07-02 13:27
- Article
- S0000174
- ID record
- 638870523635808113-1896
- ID production
- 52061
- Temperature
- 30.85
- Humidity
- 34.66
- Test duration
- 71
- Error ID
- —
- Error text
- —
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 52061 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0736 | Pass | ||
| 0.3 | Uložení teploty okolí | 30.85 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 34.66 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000174 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 1000.03626 | 900 | 1100 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 3316.37275 | 3200 | 3400 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP48/TP25,26) | 998.981858 | 900 | 1100 | Pass |
| 1.4 | DMM: Kontrola hodnoty Odporu (TP13/TP25,26) | 10030.4434 | 9500 | 10500 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP36/TP37) | 1076.12059 | 1012 | 1120 | Pass |
| 2.2 | DMM: Kontrola hodnoty Odporu (TP40/TP41) | 1034.3364 | 1012 | 1120 | Pass |
| 4.0 | DMM: Kontrola hodnoty napětí (TP22/TP25,26) | -0.735086702 | -0.75 | -0.65 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP25/TP25,26) | 0.009986895 | 0.009 | 1 | Pass |
| 5.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.03215938 | 0.025 | 0.035 | Pass |
| 5.2 | DMM: Kontrola hodnoty napětí (TP49/TP25,26) | 8.72937354 | 8.7 | 9 | Pass |
| 5.3 | DMM: Kontrola hodnoty napětí (TP17/TP25,26) | 5.00652265 | 4.9 | 5.1 | Pass |
| 5.4 | DMM: Kontrola hodnoty napětí (TP16/TP25,26) | 4.98962885 | 4.9 | 5.1 | Pass |
| 5.5 | DMM: Kontrola hodnoty napětí (TP29/TP25,26) | 4.98926084 | 4.9 | 5.1 | Pass |
| 5.6 | DMM: Kontrola hodnoty napětí (TP14/TP25,26) | 3.30920064 | 3.2 | 3.4 | Pass |
| 5.7 | DMM: Kontrola hodnoty napětí (TP5/TP25,26) | 3.30924437 | 3.2 | 3.4 | Pass |
| 5.8 | DMM: Kontrola hodnoty napětí (TP24/TP25,26) | 8.65018688 | 7.5 | 9 | Pass |
| 5.9 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0.152377262 | 0 | 0.65 | Pass |
| 6.1 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | 2.723677E-05 | -0.0001 | 0.0001 | Pass |
| 6.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 0.106798778 | -0.2 | 0.5 | Pass |
| 6.3 | NZ1: Odběr proudu ze zdroje (TP25,26/TP19) | 0.01997921 | 0.019 | 1 | Pass |
| 7.1 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 0.005970377 | < | 0.0001 | Fail |
| 7.1 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 9.2546E-05 | < | 0.0001 | Pass |
| 7.2 | DMM: Kontrola hodnoty napětí (TP20/TP25,26) | 6.00302167 | 5.95 | 7 | Pass |
| 7.3 | DMM: Kontrola hodnoty napětí (TP50/TP25,26) | 3.15781283 | > | 3 | Pass |
| 7.4 | DMM: Kontrola hodnoty napětí (TP15/TP25,26) | 0.0023618892 | 0 | 0.5 | Pass |
| 7.5 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 0.0006803291 | 0.00057 | 0.0007 | Pass |
| 7.6 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0.0001069841 | -0.001 | 0.0002 | Pass |
| 7.7 | NZ1: Odběr proudu ze zdroje (TP19/TP25,26) | 9.2546E-05 | -0.001 | 0.0001 | Pass |
| 7.8 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 8.96303752 | 8.7 | 9 | Pass |
| 9.0 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.0411394 | 0 | 0.099 | Pass |
| 9.1 | Vyhodnocení programu: [testSW] | Running... | Fail | ||
| 9.1 | Vyhodnocení programu: [testSW] | 0 | Pass | ||
| 10.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 9.2546E-05 | -0.001 | 0.0002 | Pass |
| 10.3 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 9.685854E-05 | -0.001 | 0.0002 | Pass |
| 10.4 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0.02680402 | 0.015 | 0.03 | Pass |
| 11.1 | DMM: Kontrola hodnoty proudu (TP25,26/NZ1-) | 0.14384406 | 0.13 | 1 | Pass |
| 11.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0.0263142 | 0.015 | 0.03 | Pass |
| 12.1 | NZ2: Odběr proudu ze zdroje (TP22/TP25,26) | 0.04311977 | 0.02 | 0.05 | Pass |
| 12.2 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 9.2546E-05 | -0.001 | 0.0001 | Pass |
| 12.3 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 0.02566111 | 0.015 | 0.03 | Pass |
| 13.1 | NZ1: Odběr proudu ze zdroje (TP19/DLO) | 9.2546E-05 | -0.001 | 0.0001 | Pass |
| 14.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.04584166 | 0.03 | 0.06 | Pass |
| 15.1 | Test oscilátorů | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 16.1 | Test komunikace mezi U2 a U3 přes RS485 | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.1 | Test eeprom a ověření velikosti | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 17.2 | Test SPI FLASH | 0 (0x00) | 0 (0x00) | 255 (0xff) | Pass |
| 18.1 | Analysis: hodnota na max | True | d_VCC_ADC[3383]<=d_max[3431.90596596824] | Pass | |
| 19.1 | Analysis: hodnota na max | True | d_U5V_ADC[3094]<=d_max[3112.76462370835] | Pass | |
| 19.1 | NZ2: Odběr proudu ze zdroje (TP19/TP25,26) | 0.0004260974 | < | 0.0001 | Fail |
| 19.1 | NZ2: Odběr proudu ze zdroje (TP19/TP25,26) | 8.893764E-05 | < | 0.0001 | Pass |
| 19.2 | DMM: Změřit napětí VBATT a uložit (TP20/TP25,26) | d_VBATT=5.99350254 | Pass | ||
| 19.3 | Analysis: hodnota na max | True | d_VBATT_ADC[2327]<=d_max[2348.52377243589] | Pass | |
| 20.1 | NZ2: Odběr proudu ze zdroje (TP42/TP25,26) | 0.0002274314 | -0.0001 | 0.005 | Pass |
| 20.2 | Přečti hodnotu PA4[HW_CH_DET] | 0 | 0 | 0 | Pass |
| 20.3 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 0.294286548 | 0 | 0.49 | Pass |
| 20.4 | DMM: Kontrola hodnoty napětí (TP38/TP25,26) | 11.9532282 | 11.7 | 15 | Pass |
| 21.1 | NZ2: Odběr proudu ze zdroje (TP39/TP25,26) | 8.706294E-06 | -0.0001 | 0.001 | Pass |
| 21.2 | DMM: Kontrola hodnoty napětí (TP43/TP25,26) | 11.9167179 | 11.7 | 15 | Pass |
| 22.2 | DMM: Kontrola hodnoty proudu (TP7/R15R) | 0.25403814 | 0.2425 | 0.2775 | Pass |
| 22.2 | DMM: Kontrola hodnoty proudu (TP7/R15R) | 0 | -0.0005 | 0.0005 | Pass |
| 25.1 | NZ2: Odběr proudu ze zdroje (TP45/TP25,26) | 0.199897 | > | 0.195 | Pass |
| 26.1 | NZ2: Odběr proudu ze zdroje (TP44/TP25,26) | 0.1999166 | > | 0.195 | Pass |
| 27.1 | NZ2: Odběr proudu ze zdroje (TP46/TP25,26) | 0.1999166 | > | 0.195 | Pass |
| 28.1 | NZ2: Odběr proudu ze zdroje (TP47/TP25,26) | 0.1999166 | > | 0.195 | Pass |
| 29.1 | Změřit ADC U11 AIN7, AIN8 | 8715 | 8400 | 10000 | Pass |
| 30.1 | Změřit ADC U11 AIN5, AIN6 | 8721 | 8400 | 10000 | Pass |
| 31.1 | Změřit ADC U11 AIN3, AIN4 | 8694 | 8400 | 10000 | Pass |
| 32.1 | Změřit ADC U11 AIN1, AIN2 | 8733 | 8400 | 10000 | Pass |
| 35.1 | Vyhodnocení programu: [finalSW] | Running... | Fail | ||
| 35.1 | Vyhodnocení programu: [finalSW] | 0 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-11-19 21:30 | 1607470 | — | — |