Serial 001607419

Tests5
Approved2
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-07-02 13:25 20763 638870523163806885-1517 S0000174 Fail View
2025-07-02 13:31 20764 638870526955315433-7748 S0000174 Fail View
2025-07-02 13:44 20765 638870534768314748-1725 S0000174 Fail View
2025-07-02 13:45 20766 638870534933716908-6869 S0000174 Pass View
2025-11-19 21:39 43145 638991815178806481-8241 S0004028 Pass View

Test 20765

Result
Fail
Date
2025-07-02 13:44
Article
S0000174
ID record
638870534768314748-1725
ID production
52061
Temperature
30.83
Humidity
34.76
Test duration
7
Error ID
109
Error text
DMM: Kontrola hodnoty napětí (TP49/TP25,26)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 52061 Pass
0.2 Uložení ID obsluhy 0736 Pass
0.3 Uložení teploty okolí 30.83 Pass
0.4 Uložení vlhkosti okolí 34.76 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0000174 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP2/TP3) 1000.49067 900 1100 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP4/TP3) 3313.96225 3200 3400 Pass
1.3 DMM: Kontrola hodnoty Odporu (TP48/TP25,26) 1003.61661 900 1100 Pass
1.4 DMM: Kontrola hodnoty Odporu (TP13/TP25,26) 10076.2435 9500 10500 Pass
2.1 DMM: Kontrola hodnoty Odporu (TP36/TP37) 1070.01874 1012 1120 Pass
2.2 DMM: Kontrola hodnoty Odporu (TP40/TP41) 1033.50389 1012 1120 Pass
4.0 DMM: Kontrola hodnoty napětí (TP22/TP25,26) -0.737812633 -0.75 -0.65 Pass
4.1 NZ1: Odběr proudu ze zdroje (TP25/TP25,26) 0.01001955 0.009 1 Pass
5.1 NZ1: Odběr proudu ze zdroje (TP22/TP25,26) 0.03166956 0.025 0.035 Pass
5.2 DMM: Kontrola hodnoty napětí (TP49/TP25,26) 8.69862045 8.7 9 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2025-11-19 21:39 1607419