Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001574075

Tests10
Approved1
Failures9

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-06-19 17:29 19332 638859437482648297-7083 S0000174 Fail View
2025-06-19 17:51 19333 638859450498358196-9743 S0000174 Fail View
2025-06-19 19:25 19334 638859506855758736-1694 S0000174 Fail View
2025-06-19 19:31 19335 638859510677446406-4639 S0000174 Fail View
2025-06-19 19:32 19336 638859511167312694-8973 S0000174 Fail View
2025-06-23 11:34 19793 638862680286953807-5288 S0000174 Fail View
2025-06-23 11:38 19794 638862682443933306-3913 S0000174 Fail View
2025-06-23 11:51 19795 638862690955123134-2893 S0000174 Fail View
2025-06-23 11:52 19796 638862691238883562-4487 S0000174 Fail View
2025-06-23 11:54 19797 638862692042687193-3899 S0000174 Pass View

Test 19796

Result
Fail
Date
2025-06-23 11:52
Article
S0000174
ID record
638862691238883562-4487
ID production
52059
Temperature
27.53
Humidity
43.81
Test duration
11
Error ID
130
Error text
DMM: Kontrola hodnoty napětí (TP20/TP25,26)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 52059 Pass
0.2 Uložení ID obsluhy 0540 Pass
0.3 Uložení teploty okolí 27.53 Pass
0.4 Uložení vlhkosti okolí 43.81 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0000174 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP2/TP3) 1000.88695 900 1100 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP4/TP3) 3301.84984 3200 3400 Pass
1.3 DMM: Kontrola hodnoty Odporu (TP48/TP25,26) 999.527216 900 1100 Pass
1.4 DMM: Kontrola hodnoty Odporu (TP13/TP25,26) 10051.6536 9500 10500 Pass
2.1 DMM: Kontrola hodnoty Odporu (TP36/TP37) 1064.25734 1012 1120 Pass
2.2 DMM: Kontrola hodnoty Odporu (TP40/TP41) 1041.77466 1012 1120 Pass
4.0 DMM: Kontrola hodnoty napětí (TP22/TP25,26) -0.707571059 -0.75 -0.65 Pass
4.1 NZ1: Odběr proudu ze zdroje (TP25/TP25,26) 0.009986895 0.009 1 Pass
5.1 NZ1: Odběr proudu ze zdroje (TP22/TP25,26) 0.03173487 0.025 0.035 Pass
5.2 DMM: Kontrola hodnoty napětí (TP49/TP25,26) 8.77595085 8.7 9 Pass
5.3 DMM: Kontrola hodnoty napětí (TP17/TP25,26) 4.98395245 4.9 5.1 Pass
5.4 DMM: Kontrola hodnoty napětí (TP16/TP25,26) 4.99077742 4.9 5.1 Pass
5.5 DMM: Kontrola hodnoty napětí (TP29/TP25,26) 4.99079452 4.9 5.1 Pass
5.6 DMM: Kontrola hodnoty napětí (TP14/TP25,26) 3.29268174 3.2 3.4 Pass
5.7 DMM: Kontrola hodnoty napětí (TP5/TP25,26) 3.29252724 3.2 3.4 Pass
5.8 DMM: Kontrola hodnoty napětí (TP24/TP25,26) 8.70488702 7.5 9 Pass
5.9 DMM: Kontrola hodnoty napětí (TP20/TP25,26) 0.895086451 0 0.65 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (10)
DateValueMinMax
2025-06-19 17:29 52059
2025-06-19 17:51 52059
2025-06-19 19:25 52059
2025-06-19 19:31 52059
2025-06-19 19:32 52059
2025-06-23 11:34 52059
2025-06-23 11:38 52059
2025-06-23 11:51 52059
2025-06-23 11:52 52059
2025-06-23 11:54 52059