Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001574033

Tests7
Approved1
Failures6

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-06-19 17:25 19309 638859434789588671-1955 S0000174 Fail View
2025-06-19 17:50 19310 638859450045336203-3819 S0000174 Fail View
2025-06-19 19:24 19311 638859506360104749-6703 S0000174 Fail View
2025-06-19 19:29 19312 638859509354570098-1923 S0000174 Fail View
2025-06-19 19:30 19313 638859509823457836-2332 S0000174 Fail View
2025-06-19 19:30 19314 638859510231948858-9314 S0000174 Fail View
2025-06-23 11:36 19792 638862681469422376-4685 S0000174 Pass View

Test 19792

Result
Pass
Date
2025-06-23 11:36
Article
S0000174
ID record
638862681469422376-4685
ID production
52059
Temperature
27.65
Humidity
42.12
Test duration
56
Error ID
Error text

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 52059 Pass
0.2 Uložení ID obsluhy 0540 Pass
0.3 Uložení teploty okolí 27.65 Pass
0.4 Uložení vlhkosti okolí 42.12 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0000174 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP2/TP3) 1001.43239 900 1100 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP4/TP3) 3298.35172 3200 3400 Pass
1.3 DMM: Kontrola hodnoty Odporu (TP48/TP25,26) 1001.78083 900 1100 Pass
1.4 DMM: Kontrola hodnoty Odporu (TP13/TP25,26) 10073.0622 9500 10500 Pass
2.1 DMM: Kontrola hodnoty Odporu (TP36/TP37) 1070.25097 1012 1120 Pass
2.2 DMM: Kontrola hodnoty Odporu (TP40/TP41) 1040.02388 1012 1120 Pass
4.0 DMM: Kontrola hodnoty napětí (TP22/TP25,26) -0.721408074 -0.75 -0.65 Pass
4.1 NZ1: Odběr proudu ze zdroje (TP25/TP25,26) 0.009986895 0.009 1 Pass
5.1 NZ1: Odběr proudu ze zdroje (TP22/TP25,26) 0.03183283 0.025 0.035 Pass
5.2 DMM: Kontrola hodnoty napětí (TP49/TP25,26) 8.76640057 8.7 9 Pass
5.3 DMM: Kontrola hodnoty napětí (TP17/TP25,26) 4.97039685 4.9 5.1 Pass
5.4 DMM: Kontrola hodnoty napětí (TP16/TP25,26) 5.00366366 4.9 5.1 Pass
5.5 DMM: Kontrola hodnoty napětí (TP29/TP25,26) 5.00368649 4.9 5.1 Pass
5.6 DMM: Kontrola hodnoty napětí (TP14/TP25,26) 3.30201193 3.2 3.4 Pass
5.7 DMM: Kontrola hodnoty napětí (TP5/TP25,26) 3.30202611 3.2 3.4 Pass
5.8 DMM: Kontrola hodnoty napětí (TP24/TP25,26) 8.69888491 7.5 9 Pass
5.9 DMM: Kontrola hodnoty napětí (TP20/TP25,26) 0.363686275 0 0.65 Pass
6.1 NZ1: Odběr proudu ze zdroje (TP25,26/TP19) -5.417849E-06 -0.0001 0.0001 Pass
6.2 DMM: Kontrola hodnoty napětí (TP20/TP25,26) 0.265230221 -0.2 0.5 Pass
6.3 NZ1: Odběr proudu ze zdroje (TP25,26/TP19) 0.01994655 0.019 1 Pass
7.1 NZ1: Odběr proudu ze zdroje (TP19/TP25,26) 0.005251976 < 0.0001 Fail
7.1 NZ1: Odběr proudu ze zdroje (TP19/TP25,26) 9.2546E-05 < 0.0001 Pass
7.2 DMM: Kontrola hodnoty napětí (TP20/TP25,26) 6.00317834 5.95 7 Pass
7.3 DMM: Kontrola hodnoty napětí (TP50/TP25,26) 3.17862597 > 3 Pass
7.4 DMM: Kontrola hodnoty napětí (TP15/TP25,26) 0.0863442316 0 0.5 Pass
7.5 NZ1: Odběr proudu ze zdroje (TP19/TP25,26) 0.0006150199 0.00057 0.0007 Pass
7.6 NZ2: Odběr proudu ze zdroje (TP42/TP25,26) 0.0001115573 -0.001 0.0002 Pass
7.7 NZ1: Odběr proudu ze zdroje (TP19/TP25,26) 2.723677E-05 -0.001 0.0001 Pass
7.8 DMM: Kontrola hodnoty napětí (TP38/TP25,26) 8.95290111 8.7 9 Pass
9.0 NZ1: Odběr proudu ze zdroje (TP22/TP25,26) 0.04133533 0 0.099 Pass
9.1 Vyhodnocení programu: [testSW] 0 Pass
9.1 Vyhodnocení programu: [testSW] Running... Fail
10.2 NZ1: Odběr proudu ze zdroje (TP19/DLO) 5.989139E-05 -0.001 0.0002 Pass
10.3 NZ2: Odběr proudu ze zdroje (TP42/TP25,26) 0.0001008782 -0.001 0.0002 Pass
10.4 NZ1: Odběr proudu ze zdroje (TP19/DLO) 0.02608562 0.015 0.03 Pass
11.1 DMM: Kontrola hodnoty proudu (TP25,26/NZ1-) 0.14098257 0.13 1 Pass
11.2 NZ1: Odběr proudu ze zdroje (TP19/DLO) 0.02549784 0.015 0.03 Pass
12.1 NZ2: Odběr proudu ze zdroje (TP22/TP25,26) 0.04060913 0.02 0.05 Pass
12.2 NZ1: Odběr proudu ze zdroje (TP19/DLO) -5.417849E-06 -0.001 0.0001 Pass
12.3 NZ1: Odběr proudu ze zdroje (TP19/DLO) 0.02543253 0.015 0.03 Pass
13.1 NZ1: Odběr proudu ze zdroje (TP19/DLO) 2.723677E-05 -0.001 0.0001 Pass
14.1 NZ1: Odběr proudu ze zdroje (TP22/TP25,26) 0.04535185 0.03 0.06 Pass
15.1 Test oscilátorů 0 (0x00) 0 (0x00) 0 (0x00) Pass
16.1 Test komunikace mezi U2 a U3 přes RS485 0 (0x00) 0 (0x00) 0 (0x00) Pass
17.1 Test eeprom a ověření velikosti 0 (0x00) 0 (0x00) 0 (0x00) Pass
17.2 Test SPI FLASH 0 (0x00) 0 (0x00) 255 (0xff) Pass
18.1 Analysis: hodnota na max True d_VCC_ADC[3384]<=d_max[3441.89957622724] Pass
19.1 Analysis: hodnota na max True d_U5V_ADC[3095]<=d_max[3126.0348081392] Pass
19.1 NZ2: Odběr proudu ze zdroje (TP19/TP25,26) 8.926669E-05 < 0.0001 Pass
19.2 DMM: Změřit napětí VBATT a uložit (TP20/TP25,26) d_VBATT=5.98767776 Pass
19.3 Analysis: hodnota na max True d_VBATT_ADC[2321]<=d_max[2346.09972078096] Pass
20.1 NZ2: Odběr proudu ze zdroje (TP42/TP25,26) 0.00028305 -0.0001 0.005 Pass
20.2 Přečti hodnotu PA4[HW_CH_DET] 0 0 0 Pass
20.3 DMM: Kontrola hodnoty napětí (TP38/TP25,26) 0.0181461617 0 0.49 Pass
20.4 DMM: Kontrola hodnoty napětí (TP38/TP25,26) 11.9433337 11.7 15 Pass
21.1 NZ2: Odběr proudu ze zdroje (TP39/TP25,26) 3.902824E-06 -0.0001 0.001 Pass
21.2 DMM: Kontrola hodnoty napětí (TP43/TP25,26) 11.9297128 11.7 15 Pass
22.2 DMM: Kontrola hodnoty proudu (TP7/R15R) 0.256872091 0.2425 0.2775 Pass
22.2 DMM: Kontrola hodnoty proudu (TP7/R15R) 0 -0.0005 0.0005 Pass
25.1 NZ2: Odběr proudu ze zdroje (TP45/TP25,26) 0.1998774 > 0.195 Pass
26.1 NZ2: Odběr proudu ze zdroje (TP44/TP25,26) 0.1998774 > 0.195 Pass
27.1 NZ2: Odběr proudu ze zdroje (TP46/TP25,26) 0.1998774 > 0.195 Pass
28.1 NZ2: Odběr proudu ze zdroje (TP47/TP25,26) 0.1998774 > 0.195 Pass
29.1 Změřit ADC U11 AIN7, AIN8 8732 8400 10000 Pass
30.1 Změřit ADC U11 AIN5, AIN6 8716 8400 10000 Pass
31.1 Změřit ADC U11 AIN3, AIN4 8694 8400 10000 Pass
32.1 Změřit ADC U11 AIN1, AIN2 8702 8400 10000 Pass
35.1 Vyhodnocení programu: [finalSW] Running... Fail
35.1 Vyhodnocení programu: [finalSW] 0 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (7)
DateValueMinMax
2025-06-19 17:25 52059
2025-06-19 17:50 52059
2025-06-19 19:24 52059
2025-06-19 19:29 52059
2025-06-19 19:30 52059
2025-06-19 19:30 52059
2025-06-23 11:36 52059