Serial lookup
Search a serial number to see its full test history.
Serial 001966461
Tests3
Approved0
Failures3
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-06-19 14:06 | 19487 | 638859316082742885-2782 | Fail | View | |
| 2025-08-27 10:37 | 48031 | 638918806222394021-7139 | Fail | View | |
| 2026-02-02 07:03 | 60979 | 639056090090057404-7293 | S0001604 | Fail | View |
Test 19487
- Result
- Fail
- Date
- 2025-06-19 14:06
- Article
- ID record
- 638859316082742885-2782
- ID production
- 52627
- Temperature
- 28.34
- Humidity
- 34.62
- Test duration
- 4
- Error ID
- 56
- Error text
- NZ3: Měření proudu: (TP2/TP9)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 52627 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0043 | Pass | ||
| 0.3 | Uložení teploty okolí | 28.34 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 34.62 | Pass | ||
| 0.6 | DMM: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.7 | NZ3: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.8 | EL: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 1.1 | DMM: Kontrola hodnoty Odporu (TP7/TP8) | 100.772893 | 95 | 105 | Pass |
| 2.1 | NZ3: Měření proudu: (TP2/TP9) | 0.008221599 | 0.002 | 0.008 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-02-02 07:03 | 1966461 | — | — |