Serial 001574224

Tests5
Approved1
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-06-04 10:14 17255 638846216926847352-1237 S0000174 Fail View
2025-06-04 10:15 17256 638846217112101788-1808 S0000174 Fail View
2025-06-04 10:22 17257 638846221293984599-1784 S0000174 Fail View
2025-06-04 12:14 17258 638846288878322707-8414 S0000174 Fail View
2025-11-19 19:38 43114 638991742690013592-1047 S0004028 Pass View

Test 17256

Result
Fail
Date
2025-06-04 10:15
Article
S0000174
ID record
638846217112101788-1808
ID production
52059
Temperature
27.95
Humidity
47.34
Test duration
5
Error ID
107
Error text
NZ1: Odběr proudu ze zdroje (TP22/TP25,26)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 52059 Pass
0.2 Uložení ID obsluhy 1860 Pass
0.3 Uložení teploty okolí 27.95 Pass
0.4 Uložení vlhkosti okolí 47.34 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0000174 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP2/TP3) 1002.60308 900 1100 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP4/TP3) 3292.5815 3200 3400 Pass
1.3 DMM: Kontrola hodnoty Odporu (TP48/TP25,26) 1000.869 900 1100 Pass
1.4 DMM: Kontrola hodnoty Odporu (TP13/TP25,26) 10075.1579 9500 10500 Pass
2.1 DMM: Kontrola hodnoty Odporu (TP36/TP37) 1068.02133 1012 1120 Pass
2.2 DMM: Kontrola hodnoty Odporu (TP40/TP41) 1037.90698 1012 1120 Pass
4.0 DMM: Kontrola hodnoty napětí (TP22/TP25,26) -0.724025726 -0.75 -0.65 Pass
4.1 NZ1: Odběr proudu ze zdroje (TP25/TP25,26) 0.009986895 0.009 1 Pass
5.1 NZ1: Odběr proudu ze zdroje (TP22/TP25,26) 0.04995615 0.025 0.035 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2025-11-19 19:38 1574224