Serial lookup
Search a serial number to see its full test history.
Serial 001574224
Tests5
Approved1
Failures4
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-06-04 10:14 | 17255 | 638846216926847352-1237 | S0000174 | Fail | View |
| 2025-06-04 10:15 | 17256 | 638846217112101788-1808 | S0000174 | Fail | View |
| 2025-06-04 10:22 | 17257 | 638846221293984599-1784 | S0000174 | Fail | View |
| 2025-06-04 12:14 | 17258 | 638846288878322707-8414 | S0000174 | Fail | View |
| 2025-11-19 19:38 | 43114 | 638991742690013592-1047 | S0004028 | Pass | View |
Test 17255
- Result
- Fail
- Date
- 2025-06-04 10:14
- Article
- S0000174
- ID record
- 638846216926847352-1237
- ID production
- 52059
- Temperature
- 27.95
- Humidity
- 47.34
- Test duration
- 5
- Error ID
- 107
- Error text
- NZ1: Odběr proudu ze zdroje (TP22/TP25,26)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 52059 | Pass | ||
| 0.2 | Uložení ID obsluhy | 1860 | Pass | ||
| 0.3 | Uložení teploty okolí | 27.95 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 47.34 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000174 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 1002.32689 | 900 | 1100 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 3292.46696 | 3200 | 3400 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP48/TP25,26) | 1000.72512 | 900 | 1100 | Pass |
| 1.4 | DMM: Kontrola hodnoty Odporu (TP13/TP25,26) | 10074.9597 | 9500 | 10500 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP36/TP37) | 1065.94592 | 1012 | 1120 | Pass |
| 2.2 | DMM: Kontrola hodnoty Odporu (TP40/TP41) | 1033.91862 | 1012 | 1120 | Pass |
| 4.0 | DMM: Kontrola hodnoty napětí (TP22/TP25,26) | -0.720850179 | -0.75 | -0.65 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP25/TP25,26) | 0.009986895 | 0.009 | 1 | Pass |
| 5.1 | NZ1: Odběr proudu ze zdroje (TP22/TP25,26) | 0.04995615 | 0.025 | 0.035 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-11-19 19:38 | 1574224 | — | — |