Serial lookup
Search a serial number to see its full test history.
Serial 001714019
Tests4
Approved1
Failures3
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2024-10-16 11:24 | 1693 | 638646674438963410-6694 | S0000608 | Fail | View |
| 2024-10-16 11:24 | 1694 | 638646674597581052-7981 | S0000608 | Fail | View |
| 2024-10-16 11:25 | 1695 | 638646675090128092-3002 | S0000608 | Fail | View |
| 2024-10-16 11:30 | 1696 | 638646677096495837-2439 | S0000608 | Pass | View |
Test 1694
- Result
- Fail
- Date
- 2024-10-16 11:24
- Article
- S0000608
- ID record
- 638646674597581052-7981
- ID production
- 50069
- Temperature
- 25,43
- Humidity
- 35,22
- Test duration
- 1
- Error ID
- 57
- Error text
- DMM: Kontrola hodnoty Odporu (TP2/TP3)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 50069 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0313 | Pass | ||
| 0.3 | Uložení teploty okolí | 25,43 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 35,22 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000608 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 1,09438661 | -1 | 1 | Fail |
Measurements over time
No plottable values for this measurement.
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2024-10-16 11:30 | — | — | — |