Serial 001359821
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-06-03 15:45 | 16857 | 638845551218864803-4896 | S0000608 | Fail | View |
| 2025-06-03 15:51 | 16858 | 638845554148706271-8693 | S0000608 | Pass | View |
Test 16858
- Result
- Pass
- Date
- 2025-06-03 15:51
- Article
- S0000608
- ID record
- 638845554148706271-8693
- ID production
- 52261
- Temperature
- 28.03
- Humidity
- 41.2
- Test duration
- 84
- Error ID
- —
- Error text
- —
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| Vypnutí K2.A6 (TP17,18/NZ1-) | Pass | ||||
| 0.1 | Uložení čísla výrobního příkazu | 52261 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0043 | Pass | ||
| 0.3 | Uložení teploty okolí | 28.03 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 41.2 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000608 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 2.02844653 | -1 | 5 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 7483.9119 | 7400 | 7600 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP27/TP17,18) | 10152.7564 | 9000 | 11000 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP8/TP10) | 1071.49361 | 1012 | 1120 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP6/TP17,18) | 0.002868189 | 0.0025 | 0.006 | Pass |
| 4.2 | DMM: Kontrola hodnoty napětí (TP5/TP17,18) | 11.9979642 | 11.9 | 12.1 | Pass |
| 4.3 | DMM: Kontrola hodnoty napětí (TP19/TP17,18) | 5.04530879 | 4.9 | 5.1 | Pass |
| 4.4 | DMM: Kontrola hodnoty napětí (TP20/TP17,18) | 3.29388533 | 3.2 | 3.4 | Pass |
| 4.5 | DMM: Kontrola hodnoty napětí (TP21/TP17,18) | 3.29393028 | 3.2 | 3.4 | Pass |
| 4.6 | DMM: Kontrola hodnoty napětí (TP31/TP17,18) | 3.29157803 | 3.2 | 3.4 | Pass |
| 4.7 | DMM: Kontrola hodnoty napětí (TP36/TP17,18) | 5.04546744 | 4.9 | 5.1 | Pass |
| 4.8 | DMM: Kontrola hodnoty napětí (TP38/TP17,18) | 3.29399954 | 3.2 | 3.4 | Pass |
| 5.0 | DMM: Kontrola hodnoty napětí (TP12/TP17,18) | 0.000205649439 | < | 0.1 | Pass |
| 5.1 | DMM: Kontrola hodnoty napětí (TP12/TP17,18) | 2.82870069 | 2.54 | 3.14 | Pass |
| 8.1 | Vyhodnocení programu: [testSW] | Running... | Fail | ||
| 8.1 | Vyhodnocení programu: [testSW] | 0 | Pass | ||
| 12.1 | Test komunikace mezi U2 a U3 přes RS485 | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 13.1 | DMM: Změřit napětí + 3V3 a uložit (TP20/TP17,18) | d_3V3=3.29327358 | Pass | ||
| 13.2 | DMM: Změřit napětí VCC_PER a uložit (TP5/TP17,18) | d_VCC_PER=11.9905413 | Pass | ||
| 13.3 | Načtení hodnoty ADC z PC4 (VBATT_ADC) a uložení | d_VBATT_ADC=3172 | Pass | ||
| 13.4 | Analysis: hodnota na max | True | d_VBATT_ADC[3172]<=d_max[3206.51222164859] | Pass | |
| 13.5 | Analysis: hodnota na min | True | d_VBATT_ADC[3172]>=d_min[3146.51222164859] | Pass | |
| 15.1 | DMM: Kontrola hodnoty napětí (TP32/TP17,18) | 3.27475021 | > | 3 | Pass |
| 15.2 | DMM: Kontrola hodnoty napětí (TP32/TP17,18) | 0.0024910532 | < | 0.1 | Pass |
| 16.1 | DMM: Kontrola hodnoty napětí (TP33/TP17,18) | 3.27495903 | > | 3 | Pass |
| 16.2 | DMM: Kontrola hodnoty napětí (TP33/TP17,18) | 0.00204162546 | < | 0.1 | Pass |
| 17.1 | DMM: Kontrola hodnoty napětí (TP34/TP17,18) | 3.2747472 | > | 3 | Pass |
| 17.2 | DMM: Kontrola hodnoty napětí (TP34/TP17,18) | 0.0017472582 | < | 0.1 | Pass |
| 18.1 | DMM: Kontrola hodnoty napětí (TP35/TP17,18) | 3.27473952 | > | 3 | Pass |
| 18.2 | DMM: Kontrola hodnoty napětí (TP35/TP17,18) | 0.00158947979 | < | 0.1 | Pass |
| 19.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 3.27446649 | > | 3 | Pass |
| 19.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00135975123 | < | 0.1 | Pass |
| 19.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00116455574 | < | 0.1 | Pass |
| 19.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00115958266 | < | 0.1 | Pass |
| 19.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00116594643 | < | 0.1 | Pass |
| 20.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.000795290966 | < | 0.1 | Pass |
| 20.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 3.29075313 | > | 3 | Pass |
| 20.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00113508637 | < | 0.1 | Pass |
| 20.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00112878437 | < | 0.1 | Pass |
| 20.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00113487281 | < | 0.1 | Pass |
| 21.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.000840585465 | < | 0.1 | Pass |
| 21.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00133586883 | < | 0.1 | Pass |
| 21.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 3.29093481 | > | 3 | Pass |
| 21.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00114506241 | < | 0.1 | Pass |
| 21.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00115983467 | < | 0.1 | Pass |
| 22.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.000957276174 | < | 0.1 | Pass |
| 22.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00135745059 | < | 0.1 | Pass |
| 22.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00117660488 | < | 0.1 | Pass |
| 22.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 3.29093323 | > | 3 | Pass |
| 22.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00116775781 | < | 0.1 | Pass |
| 23.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.000829044007 | < | 0.1 | Pass |
| 23.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00132671637 | < | 0.1 | Pass |
| 23.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00115148356 | < | 0.1 | Pass |
| 23.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00116929357 | < | 0.1 | Pass |
| 23.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 3.29074717 | > | 3 | Pass |
| 24.1 | NZ2: Odběr proudu ze zdroje (TP37/TP17,18) | 3.282446E-06 | < | 0.0001 | Pass |
| 24.2 | NZ2: Odběr proudu ze zdroje (TP37/TP17,18) | 0.05039668 | 0.045 | 0.055 | Pass |
| 25.1 | NZ2: Odběr proudu ze zdroje (TP47/TP17,18) | -3.859168E-08 | < | 0.0005 | Pass |
| 25.2 | NZ2: Odběr proudu ze zdroje (TP47/TP17,18) | 0.05000439 | > | 0.04 | Pass |
| 26.1 | NZ2: Odběr proudu ze zdroje (TP45/TP17,18) | 0.0100108 | > | 0.009 | Pass |
| 26.2 | NZ2: Odběr proudu ze zdroje (TP45/TP17,18) | 0.0009190165 | < | 0.002 | Pass |
| 27.1 | NZ2: Kontrola hodnoty proudu (TP46/TP17,18) | 0.01003042 | > | 0.009 | Pass |
| 27.2 | NZ2: Kontrola hodnoty proudu (TP46/TP17,18) | 0.0009190165 | < | 0.002 | Pass |
| 29.1 | Vyhodnocení programu: [finalSW] | Running... | Fail | ||
| 29.1 | Vyhodnocení programu: [finalSW] | 0 | Pass |
Measurements over time
No plottable values for this measurement.
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-06-03 15:45 | — | — | — |
| 2025-06-03 15:51 | — | — | — |