Serial 001606970
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-06-02 18:15 | 16368 | 638844777416797151-4077 | S0000608 | Fail | View |
| 2025-06-02 21:33 | 16369 | 638844895294034003-2296 | S0000608 | Pass | View |
Test 16369
- Result
- Pass
- Date
- 2025-06-02 21:33
- Article
- S0000608
- ID record
- 638844895294034003-2296
- ID production
- 52053
- Temperature
- 28.34
- Humidity
- 47.48
- Test duration
- 89
- Error ID
- —
- Error text
- —
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| Vypnutí K2.A6 (TP17,18/NZ1-) | Pass | ||||
| 0.1 | Uložení čísla výrobního příkazu | 52053 | Pass | ||
| 0.2 | Uložení ID obsluhy | 0043 | Pass | ||
| 0.3 | Uložení teploty okolí | 28.34 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 47.48 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0000608 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP2/TP3) | 2.01829099 | -1 | 5 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP4/TP3) | 7498.0607 | 7400 | 7600 | Pass |
| 1.3 | DMM: Kontrola hodnoty Odporu (TP27/TP17,18) | 10154.3128 | 9000 | 11000 | Pass |
| 2.1 | DMM: Kontrola hodnoty Odporu (TP8/TP10) | 1071.80073 | 1012 | 1120 | Pass |
| 4.1 | NZ1: Odběr proudu ze zdroje (TP6/TP17,18) | 0.002868189 | 0.0025 | 0.006 | Pass |
| 4.2 | DMM: Kontrola hodnoty napětí (TP5/TP17,18) | 11.9979235 | 11.9 | 12.1 | Pass |
| 4.3 | DMM: Kontrola hodnoty napětí (TP19/TP17,18) | 4.96962099 | 4.9 | 5.1 | Pass |
| 4.4 | DMM: Kontrola hodnoty napětí (TP20/TP17,18) | 3.29011848 | 3.2 | 3.4 | Pass |
| 4.5 | DMM: Kontrola hodnoty napětí (TP21/TP17,18) | 3.29004229 | 3.2 | 3.4 | Pass |
| 4.6 | DMM: Kontrola hodnoty napětí (TP31/TP17,18) | 3.28904114 | 3.2 | 3.4 | Pass |
| 4.7 | DMM: Kontrola hodnoty napětí (TP36/TP17,18) | 4.96984839 | 4.9 | 5.1 | Pass |
| 4.8 | DMM: Kontrola hodnoty napětí (TP38/TP17,18) | 3.28998641 | 3.2 | 3.4 | Pass |
| 5.0 | DMM: Kontrola hodnoty napětí (TP12/TP17,18) | 0.000243547414 | < | 0.1 | Pass |
| 5.1 | DMM: Kontrola hodnoty napětí (TP12/TP17,18) | 2.83817574 | 2.54 | 3.14 | Pass |
| 8.1 | Vyhodnocení programu: [testSW] | 0 | Pass | ||
| 12.1 | Test komunikace mezi U2 a U3 přes RS485 | 0 (0x00) | 0 (0x00) | 0 (0x00) | Pass |
| 13.1 | DMM: Změřit napětí + 3V3 a uložit (TP20/TP17,18) | d_3V3=3.28904387 | Pass | ||
| 13.2 | DMM: Změřit napětí VCC_PER a uložit (TP5/TP17,18) | d_VCC_PER=11.99033 | Pass | ||
| 13.3 | Načtení hodnoty ADC z PC4 (VBATT_ADC) a uložení | d_VBATT_ADC=3174 | Pass | ||
| 13.4 | Analysis: hodnota na max | True | d_VBATT_ADC[3174]<=d_max[3210.54116676771] | Pass | |
| 13.5 | Analysis: hodnota na min | True | d_VBATT_ADC[3174]>=d_min[3150.54116676771] | Pass | |
| 15.1 | DMM: Kontrola hodnoty napětí (TP32/TP17,18) | 3.28124994 | > | 3 | Pass |
| 15.2 | DMM: Kontrola hodnoty napětí (TP32/TP17,18) | 0.00207961726 | < | 0.1 | Pass |
| 16.1 | DMM: Kontrola hodnoty napětí (TP33/TP17,18) | 3.28106555 | > | 3 | Pass |
| 16.2 | DMM: Kontrola hodnoty napětí (TP33/TP17,18) | 0.00266063786 | < | 0.1 | Pass |
| 17.1 | DMM: Kontrola hodnoty napětí (TP34/TP17,18) | 3.28105095 | > | 3 | Pass |
| 17.2 | DMM: Kontrola hodnoty napětí (TP34/TP17,18) | 0.00252300831 | < | 0.1 | Pass |
| 18.1 | DMM: Kontrola hodnoty napětí (TP35/TP17,18) | 3.28109807 | > | 3 | Pass |
| 18.2 | DMM: Kontrola hodnoty napětí (TP35/TP17,18) | 0.00292732542 | < | 0.1 | Pass |
| 19.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 3.27013352 | > | 3 | Pass |
| 19.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00145724136 | < | 0.1 | Pass |
| 19.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00128246779 | < | 0.1 | Pass |
| 19.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00126645334 | < | 0.1 | Pass |
| 19.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00128734657 | < | 0.1 | Pass |
| 20.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.000956646361 | < | 0.1 | Pass |
| 20.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 3.28622506 | > | 3 | Pass |
| 20.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00127230319 | < | 0.1 | Pass |
| 20.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00124259309 | < | 0.1 | Pass |
| 20.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00122962357 | < | 0.1 | Pass |
| 21.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.000961376085 | < | 0.1 | Pass |
| 21.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00142880834 | < | 0.1 | Pass |
| 21.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 3.28669191 | > | 3 | Pass |
| 21.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00126685581 | < | 0.1 | Pass |
| 21.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00125365436 | < | 0.1 | Pass |
| 22.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.00150690036 | < | 0.1 | Pass |
| 22.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00146224902 | < | 0.1 | Pass |
| 22.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.00129005548 | < | 0.1 | Pass |
| 22.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 3.28669746 | > | 3 | Pass |
| 22.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 0.00128057441 | < | 0.1 | Pass |
| 23.1 | DMM: Kontrola hodnoty napětí (TP40/TP17,18) | 0.000959912178 | < | 0.1 | Pass |
| 23.2 | DMM: Kontrola hodnoty napětí (TP41/TP17,18) | 0.00144729845 | < | 0.1 | Pass |
| 23.3 | DMM: Kontrola hodnoty napětí (TP42/TP17,18) | 0.001268906 | < | 0.1 | Pass |
| 23.4 | DMM: Kontrola hodnoty napětí (TP43/TP17,18) | 0.00125786263 | < | 0.1 | Pass |
| 23.5 | DMM: Kontrola hodnoty napětí (TP44/TP17,18) | 3.28652338 | > | 3 | Pass |
| 24.1 | NZ2: Odběr proudu ze zdroje (TP37/TP17,18) | 2.897519E-06 | < | 0.0001 | Pass |
| 24.2 | NZ2: Odběr proudu ze zdroje (TP37/TP17,18) | 0.05129893 | 0.045 | 0.055 | Pass |
| 25.1 | NZ2: Odběr proudu ze zdroje (TP47/TP17,18) | -1.04215E-06 | < | 0.0005 | Pass |
| 25.2 | NZ2: Odběr proudu ze zdroje (TP47/TP17,18) | 0.05000439 | > | 0.04 | Pass |
| 26.1 | NZ2: Odběr proudu ze zdroje (TP45/TP17,18) | 0.01003042 | > | 0.009 | Pass |
| 26.2 | NZ2: Odběr proudu ze zdroje (TP45/TP17,18) | 0.0009217189 | < | 0.002 | Pass |
| 27.1 | NZ2: Kontrola hodnoty proudu (TP46/TP17,18) | 0.01003042 | > | 0.009 | Pass |
| 27.2 | NZ2: Kontrola hodnoty proudu (TP46/TP17,18) | 0.0009171934 | < | 0.002 | Pass |
| 29.1 | Vyhodnocení programu: [finalSW] | Running... | Fail | ||
| 29.1 | Vyhodnocení programu: [finalSW] | 0 | Pass |
Measurements over time
No plottable values for this measurement.
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2025-06-02 21:33 | — | — | — |