Serial lookup
Search a serial number to see its full test history.
Serial 001854912
Tests4
Approved0
Failures4
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-05-27 08:50 | 15712 | 638839254340749799-9558 | Fail | View | |
| 2025-05-27 09:11 | 15713 | 638839267093716200-7710 | Fail | View | |
| 2025-08-27 10:18 | 47981 | 638918795149673388-5534 | Fail | View | |
| 2026-02-02 07:10 | 60962 | 639056094488600742-8350 | S0001604 | Fail | View |
Test 15712
- Result
- Fail
- Date
- 2025-05-27 08:50
- Article
- ID record
- 638839254340749799-9558
- ID production
- 51291
- Temperature
- 26.16
- Humidity
- 37.13
- Test duration
- 4
- Error ID
- 56
- Error text
- NZ3: Měření proudu: (TP2/TP9)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 51291 | Pass | ||
| 0.2 | Uložení ID obsluhy | 1699 | Pass | ||
| 0.3 | Uložení teploty okolí | 26.16 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 37.13 | Pass | ||
| 0.6 | DMM: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.7 | NZ3: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.8 | EL: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 1.1 | DMM: Kontrola hodnoty Odporu (TP7/TP8) | 101.01539 | 95 | 105 | Pass |
| 2.1 | NZ3: Měření proudu: (TP2/TP9) | 0.001762111 | 0.002 | 0.008 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-02-02 07:10 | 1854912 | — | — |