Serial lookup
Search a serial number to see its full test history.
Serial 001854840
Tests4
Approved0
Failures4
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-05-27 06:27 | 15645 | 638839168487410688-3017 | Fail | View | |
| 2025-05-27 08:24 | 15646 | 638839238544882292-3005 | Fail | View | |
| 2025-08-27 10:12 | 47978 | 638918791220684694-5170 | Fail | View | |
| 2026-02-02 07:12 | 60960 | 639056095323922417-1433 | S0001604 | Fail | View |
Test 15645
- Result
- Fail
- Date
- 2025-05-27 06:27
- Article
- ID record
- 638839168487410688-3017
- ID production
- 51291
- Temperature
- 25.67
- Humidity
- 38.11
- Test duration
- 4
- Error ID
- 56
- Error text
- NZ3: Měření proudu: (TP2/TP9)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.1 | Uložení čísla výrobního příkazu | 51291 | Pass | ||
| 0.2 | Uložení ID obsluhy | 1699 | Pass | ||
| 0.3 | Uložení teploty okolí | 25.67 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 38.11 | Pass | ||
| 0.6 | DMM: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.7 | NZ3: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 0.8 | EL: Status? | 0000000000000000 | xxxxxxxxx000000x | Pass | |
| 1.1 | DMM: Kontrola hodnoty Odporu (TP7/TP8) | 100.706303 | 95 | 105 | Pass |
| 2.1 | NZ3: Měření proudu: (TP2/TP9) | 0.008189207 | 0.002 | 0.008 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (1)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-02-02 07:12 | 1854840 | — | — |