Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial S0001604

Tests10
Approved6
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-05-26 16:48 15563 638838677269105816-3443 Pass View
2025-05-26 17:45 15564 638838711047514161-5359 Pass View
2025-05-26 17:49 15565 638838713491597266-4292 Pass View
2025-05-26 17:56 15566 638838717742529823-3090 Pass View
2025-05-26 18:10 15567 638838726386195291-6518 Pass View
2025-06-19 12:13 19680 638859248122377470-2879 Pass View
2025-08-27 10:37 48045 638918806570256510-7115 Fail View
2025-08-27 10:38 48046 638918806942969498-8728 Fail View
2026-02-02 07:01 60983 639056088934730439-1194 S0001604 Fail View
2026-02-16 14:14 63361 639068444401055252-8722 S0001604 Fail View

Test 15564

Result
Pass
Date
2025-05-26 17:45
Article
ID record
638838711047514161-5359
ID production
51291
Temperature
26.5
Humidity
36.07
Test duration
12
Error ID
Error text

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 51291 Pass
0.2 Uložení ID obsluhy 1358 Pass
0.3 Uložení teploty okolí 26.5 Pass
0.4 Uložení vlhkosti okolí 36.07 Pass
0.6 DMM: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.7 NZ3: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.8 EL: Status? 0000000000000000 xxxxxxxxx000000x Pass
1.1 DMM: Kontrola hodnoty Odporu (TP7/TP8) 100.576366 95 105 Pass
2.1 NZ3: Měření proudu: (TP2/TP9) 0.007540901 0.002 0.008 Pass
2.2 EL: Range? 61.2 61.2 61.2 Pass
2.3 EL: Current? 0.02 0.018 0.022 Pass
2.4 EL: Měření napětí: U_OUT 5.150882 5 5.5 Pass
3.1 EL: Měření proudu: (TP5/TP6) 1.999852 1.9 2.1 Pass
3.2 NZ3: Měření proudu: (TP2/TP9) 0.4134069 0.36 0.46 Pass
3.3 EL: Měření napětí: (TP5/TP6) 5.321903 4.75 5.5 Pass
4.1 EL: Měření proudu: (TP5/TP6) 0.7132937 < 1 Pass
5.1 EL: Měření proudu: (TP5/TP6) 1.999819 1.9 2.1 Pass
5.2 NZ3: Měření proudu: (TP2/TP9) 0.4134069 0.36 0.46 Pass
5.3 EL: Měření napětí: (TP5/TP6) 5.316455 4.75 5.5 Pass
6.1 EL: Měření proudu: (TP5/TP6) 0.0006451382 < 0.002 Pass
6.2 NZ3: Měření proudu: (TP2/TP9) 4.52102E-05 < 0.001 Pass
7.1 EL: Měření proudu: (TP5/TP6) 1.999815 1.9 2.1 Pass
7.2 NZ3: Měření proudu: (TP2/TP9) 0.4417776 0.36 0.46 Pass
7.3 EL: Měření napětí: (TP5/TP6) 5.318939 4.75 5.5 Pass

Measurements over time

No plottable values for this measurement.

Readings (2)
DateValueMinMax
2026-02-02 07:01