Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001855524

Tests5
Approved0
Failures5

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-05-26 06:48 15301 638838317048956924-4070 Fail View
2025-05-26 06:49 15302 638838317547023082-4518 Fail View
2025-05-26 10:58 15303 638838467119366015-6266 Fail View
2025-08-27 10:19 47998 638918795790750747-2717 Fail View
2026-02-02 07:11 60971 639056094681519648-1523 S0001604 Fail View

Test 15302

Result
Fail
Date
2025-05-26 06:49
Article
ID record
638838317547023082-4518
ID production
51291
Temperature
25.21
Humidity
39.84
Test duration
4
Error ID
56
Error text
NZ3: Měření proudu: (TP2/TP9)

Measurement lines

StepNameValueMinMaxResult
0.1 Uložení čísla výrobního příkazu 51291 Pass
0.2 Uložení ID obsluhy 1699 Pass
0.3 Uložení teploty okolí 25.21 Pass
0.4 Uložení vlhkosti okolí 39.84 Pass
0.6 DMM: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.7 NZ3: Status? 0000000000000000 xxxxxxxxx000000x Pass
0.8 EL: Status? 0000000000000000 xxxxxxxxx000000x Pass
1.1 DMM: Kontrola hodnoty Odporu (TP7/TP8) 100.336261 95 105 Pass
2.1 NZ3: Měření proudu: (TP2/TP9) 0.008068386 0.002 0.008 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2026-02-02 07:11 1855524