Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001791608

Tests4
Approved1
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-04 16:36 149 638610573698086416-6232 S0001055 Fail View
2024-09-04 17:01 150 638610588626833345-1694 S0001055 Fail View
2024-09-23 08:53 529 638626711478467811-3483 S0001055 Fail View
2024-12-05 15:14 5429 638690047895005987-2614 S0001055 Pass View

Test 149

Result
Fail
Date
2024-09-04 16:36
Article
S0001055
ID record
638610573698086416-6232
ID production
49267
Temperature
31,46
Humidity
32,9
Test duration
46
Error ID
297
Error text
DMM: Měření napětí (TP49/TP52)

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 31,46 Pass
0.4 Uložení vlhkosti okolí 32,9 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,577488478 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999,395492 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,001294968 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02437173 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9718455 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,9984835 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,8873726 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4,99324306 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,30766587 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,30768633 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,67381263 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,67093454 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,67055086 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,522020005 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,7997172 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02428921 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 1,976003 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,6919174 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,2070071 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,58618215 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,02547974 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3843 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4084 4000 4096 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2025 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2024 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4084 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2026 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2025 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,30371363 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,00352029435 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,30507412 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,0034874562 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,30342489 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,00367028657 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,30361839 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,00354605724 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 49 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995,0929 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995,0929 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 5,62560459 13,3 14,7 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2024-09-23 08:53 25.82
2024-12-05 15:14 25.6