Serial 001791579

Tests26
Approved0
Failures26

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-04 14:18 117 638610491010391758-7082 S0001055 Fail View
2024-09-04 14:45 118 638610506974024329-1251 S0001055 Fail View
2024-09-04 14:56 119 638610513558362910-7362 S0001055 Fail View
2024-09-23 08:48 524 638626708553972701-4829 S0001055 Fail View
2024-12-05 15:08 5423 638690044640990310-1385 S0001055 Fail View
2024-12-05 15:24 5424 638690054090776328-4412 S0001055 Fail View
2025-09-05 11:32 25772 638926615087314204-9021 S0001055 Fail View
2025-11-06 17:25 40594 638980430860671035-2619 S0001055 Fail View
2026-07-09 15:02 77754 639192061011499505-1916 S0001055 Fail View
2026-07-09 15:02 77755 639192061503487785-9949 S0001055 Fail View
2026-07-09 15:05 77756 639192062885456120-7661 S0001055 Fail View
2026-07-09 15:44 77785 639192086590841204-9526 S0001055 Fail View
2026-08-11 04:57 81275 639220209806147612-1733 S0001055 Fail View
2026-08-11 04:57 81276 639220210442951964-9514 S0001055 Fail View
2026-08-11 04:58 81277 639220210750082046-3964 S0001055 Fail View
2026-09-23 05:14 86086 639257372649206631-6164 S0001055 Fail View
2026-09-23 05:15 86087 639257373282538885-1747 S0001055 Fail View
2026-09-23 05:16 86088 639257373681161380-8130 S0001055 Fail View
2026-09-23 05:25 86093 639257379250356497-3217 S0001055 Fail View
2026-09-23 05:32 86098 639257383081671968-1274 S0001055 Fail View
2026-09-23 05:32 86099 639257383338221827-9069 S0001055 Fail View
2026-09-23 05:34 86100 639257384037053788-2817 S0001055 Fail View
2026-09-23 05:36 86101 639257385234025505-4942 S0001055 Fail View
2026-09-23 05:38 86102 639257386543478842-9631 S0001055 Fail View
2026-09-23 05:44 86103 639257390023852283-1687 S0001055 Fail View
2026-09-23 05:45 86104 639257390762551602-3218 S0001055 Fail View

Test 118

Result
Fail
Date
2024-09-04 14:45
Article
S0001055
ID record
638610506974024329-1251
ID production
49267
Temperature
31,43
Humidity
33,12
Test duration
59
Error ID
358
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 31,43 Pass
0.4 Uložení vlhkosti okolí 33,12 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,718043205 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 995,717411 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,0006820239 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02378825 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9746271 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,9984079 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,8331081 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4,99198183 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,30649362 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,30649103 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,67425187 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,67053269 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,66965918 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,505425623 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,7522982 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02384424 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2,049043 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,6802611 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,2491779 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,62807817 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,02512612 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3828 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2024 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2025 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2012 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2026 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2026 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,30198095 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,00351598496 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,30322939 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,00350566339 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,30181938 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,00363379768 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,30196075 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,00353166774 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 51 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19994,9554 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19994,9554 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14,0033238 13,3 14,7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19994,9479 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19994,9554 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14,0117486 13,3 14,7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19994,9516 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19994,9539 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14,0095682 13,3 14,7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0,00100264893 < 0,5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2254 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2261 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2259 Pass
20.0.5 Analysis: VA VA[2254] 2210 2340 Pass
20.0.6 Analysis: VB VB[2261] 2210 2340 Pass
20.0.7 Analysis: VC VC[2259] 2210 2340 Pass
20.1.3 TestSW: [ADC_PA1] sense B 2099 1996[VB] 2096[VB] Fail
20.1.2 TestSW: [ADC_PA0] sense A 2420 2419[VA] 2519[VA] Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989883 4,7 5,3 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0,03764138 < 0,06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (18)
DateValueMinMax
2026-07-09 15:02 1.001 10
2026-07-09 15:02 0.972 10
2026-07-09 15:05 0.962 10
2026-07-09 15:44 0.957 10
2026-08-11 04:57 0.769 10
2026-08-11 04:57 0.759 10
2026-08-11 04:58 0.75 10
2026-09-23 05:14 0.784 10
2026-09-23 05:15 0.777 10
2026-09-23 05:16 0.978 10
2026-09-23 05:25 0.933 10
2026-09-23 05:32 0.802 10
2026-09-23 05:32 0.784 10
2026-09-23 05:34 0.798 10
2026-09-23 05:36 0.777 10
2026-09-23 05:38 0.777 10
2026-09-23 05:44 0.782 10
2026-09-23 05:45 0.782 10