Testing Portal everyone (auth disabled)

← Portfolio

S0004684

Diagnostics

Deterministic checks over the selected window — every statement is computed from the data, nothing is generated.

Warning

Pass rate below target

Pass rate is 94.07% (222 of 236 tests passed, 14 failed) against a target of 98%.

Warning

5 serial number(s) failed repeatedly

Worst unit 002490180 failed 4 times (last on 2026-09-02 05:37). Repeatedly failing units usually indicate a real hardware defect rather than a flaky test.Inspect 002490180 →

Info

No historical comparison

Historical comparison is not available for the selected window (no tests in the equally long window before it).

Info

Most frequent failure mode

Error 144 — "DMM: Měření napětí: U_BAT naprázdno (TP1/TP5)" occurred 3 times, 21.4% of all 14 failures in the window.

Info

Most-failing measurement step

Measurement step 3.2 — "DMM: Měření napětí: U_BAT naprázdno (TP1/TP5)" failed 3 times across the window's 14 failed tests.

Repeatedly failing units

SerialFailed testsLast failure
002490180 4 2026-09-02 05:37 Open
002490027 2 2026-07-31 06:51 Open
002490217 2 2026-07-31 05:53 Open
002490149 2 2026-07-31 05:30 Open
002023137 2 2026-05-12 10:59 Open