Deterministic checks over the selected window — every statement is computed from the data, nothing is generated.

Critical

Pass rate far below target

Pass rate is 66.35% (1,037 of 1,563 tests passed, 526 failed) against a target of 98%.

Warning

5 serial number(s) failed repeatedly

Worst unit C00000651 failed 11 times (last on 2026-08-20 07:21). Repeatedly failing units usually indicate a real hardware defect rather than a flaky test.Inspect C00000651 →

Info

No historical comparison

Historical comparison is not available for the selected window (no tests in the equally long window before it).

Info

Most frequent failure mode

Error 218 — "TestSW: test oscilátoru ON" occurred 173 times, 32.9% of all 526 failures in the window.

Info

Most-failing measurement step

Measurement step 3.6.5 — "DMM: Měření zkratu: RE6 - BE (TP45/TP44) SHORT" failed 38 times across the window's 526 failed tests.

Repeatedly failing units

SerialFailed testsLast failure
C00000651 11 2026-08-20 07:21 Open
C00000710 9 2026-08-20 07:25 Open
C00000804 9 2026-08-20 07:23 Open
C00001234 8 2025-11-17 15:00 Open
C00000322 7 2025-12-12 14:28 Open